Vaillant TM-AG2 V132_G2 PCB · 0020092356 · Circuit 0020092344
Application to the exact variant pending confirmation. To be confirmed: it manages the ignition, flame modulation, safety features, and communication of the boiler. This one has a terminal block marked RT 24 V, RT 230 V, and BUS. It is suspected if the boiler does not respond to the panel, restarts, or shows erratic errors.
- Type of part
- Vaillant
- Status
- Refurbished
- internal SKU
- PLC180
- Warranty
- 1 year
Compatible Vaillant boilers
Vaillant. 0 verified compatibilities. There are 3 other models that we are still checking.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Vaillant VMW 226/3-3 | Vaillant | Unconfirmed |
|---|---|---|
| Vaillant VMW ES 255/4-7 turboTEC Exclusive | Vaillant | Unconfirmed |
| Vaillant VMW ES 21/245/4-5 B3 | Vaillant | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Please confirm: Look for 0020092356 on your PCB: it is usually printed on the circuit or on a side sticker (located under the red connector).
- Compare 0020092344, TM-AG2 V132_G2, PM-01, and 7011 0045 R. A difference of one digit (0020092355) is already another reference.
- Check the terminals: RT 24 V~ on terminals 7-8-9, RT 230 V~ on 3-4-5, and BUS with polarity − / + (inventory of this unit).
- Don't rely solely on the model: they provide different lists. Check the full name on the rating plate.
- Any questions? Send us a photo of the label of your PCB and the specifications plate of the boiler from Contact, or call 911 17 77 77.
Symptoms that require diagnosis in the Vaillant.
Common symptoms and faults
- 01
The boiler does not ignite or respond to any commands from the front panel.
Cause: among the symptoms of this PCB. Before replacing it, check that it is receiving power.
- 02
Erratic and intermittent fault codes, or spontaneous restarts with the boiler running.
Cause: To confirm: they are associated with this PCB. Note the codes and consult the manual for your model.
- 03
You can hear stuck relays or see burnt tracks or oxidation on the circuit.
Cause: To confirm: stuck relays prevent the burner from functioning correctly.
- 04
The boiler does not ignite: after three attempts without a flame, the fault code F.28 appears and it goes into fault mode.
Cause: Gas shortage or ignition failure, faulty electrodes or damaged PCB.
If it repeats, have a technician check it. Do not attempt to reset multiple times in a row.
- 05
The boiler shuts down during operation and the restart fails (fault code F.29).
Cause: Temporary gas cut, gas recirculation, condensates, or faulty grounding.
Have a technician check it.
- 06
The gas valve does not activate: the boiler stops with fault code F.61.
Cause: Fault in the wiring or in the coils of the gas valve, or faulty PCB.
Have a technician check it.
Vaillant fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F.28 | Start-up fault: after three attempts without flame, the boiler goes into fault. | If it repeats, have a technician check it: it could be the gas, the electrodes, or the PCB. |
| F.29 | Flame loss during operation and failed reignition. | If it repeats, have a technician check it: it could be the gas supply, the flue gas recirculation, the grounding, or the ignition. |
| F.61 | The gas valve does not activate properly: fault in the wiring, coils, or PCB. | Have a technician check it. Point to the PCB if the wiring of the gas valve is correct. |
| F.62 | The gas valve takes time to close after the flame goes out. | Have a technician check it: it could be the gas valve, the electrode, or the PCB. |
| F.63 | Fault in the memory of the PCB (EEPROM). | It usually points to the PCB: have a technician check it. |
| F.67 | The flame signal is not valid: fault in the electronics or ionization. | If it goes out when turning on, have a technician check the PCB and the ionization. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Vaillant
- Uniclima internal SKU
- PLC180
- Brand
- Vaillant
- Type of part
- Vaillant
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Screen printing of the terminal block
- 21V; BUS; RT24V; 230V~; RT230V~; L; N
- Inventory — RT 24 V~
- terminals 7-8-9
- Inventory — RT 230 V~
- terminals 3-4-5
- Inventory — BUS
- polarity − / +
- Inventory — Point/label on PCB
- 5 V
- Inventory — Application indicated in inventory
- VMW ES 21/245/4-5 B3
- Inventory — Marked code
- 0020092356; 7011 0045 R; 0020092344; TC-AG2; TL-AG2; PM-01; 0020197136; 50714 12 05; 36/16.2; 0020045379
- Data (without manufacturer's sheet) — Dimensions
- 250 × 165 × 35 mm
- Data (without manufacturer's sheet) — Weight
- 0.5 kg (: 0.40 kg for 0020092344) ·
- Identification — Marked designation
- TM-AG2 V132_G2
- Identification — Marked code
- 0020092356; 7011 0045 R
- Identification — Marked code
- 0020092344; TC-AG2; TL-AG2; PM-01
- Identification — Marked code
- 0020197136; 50714 12 05; 36/16.2
- Identification — Marked code
- 0020045379
- Serigrafia de regleta
- 21V; BUS; RT24V; 230V~; RT230V~; L; N
- Inventory data — RT 24 V~
- terminals 7-8-9
- Inventory data — RT 230 V~
- terminals 3-4-5
- Inventory data — BUS
- polarity − / +
- Inventory data — Point/label on PCB
- 5 V
- Inventory data — Application indicated in inventory
- VMW ES 21/245/4-5 B3
- Inventory data — Marked code
- 0020092356; 7011 0045 R; 0020092344; TC-AG2; TL-AG2; PM-01; 0020197136; 50714 12 05; 36/16.2; 0020045379
- Pending applications to verify
- VMW ES 21/245/4-5 B3 — noted compatibility; pending confirmation by variant. Registered application: for your product 10954 ("PCB Vaillant (0020092356)"): VMW ES 255/4-7. Pending verification with the manufacturer's documentation for the reference and physical variant; this commercial statement does not certify compatibility or interchangeability.
- To confirm: Symptoms from the commercial list, not from a Vaillant manual: that a technician confirms the fault before declaring the PCB faulty.
- Without an official fault table read for the VMW ES 21/245/4-5 B3: this document does not associate any fault code with the PCB.
- To confirm: Vaillant VMW 226/3-3 — (its in is from the same seller)
- Vaillant VMW ES 255/4-7 turboTEC Exclusive — (other)
- Not compatible or excluded: Vaillant VMW 236/3-5 (ecoTEC plus) — A list of spare parts assigns the PCB 0020132764; only with this one.
- Do not confuse: 0020092355 — Vaillant PCB with a different number; the one for the atmoTEC VC DE 104/4-7 — It is another code; this one has PM-01 and 7011 0045 R.
- Do not confuse: 0020136649 — PCB for VMW 21/245/4-5 and 255/4-7; another sheet, for VC/VCW — It is not confirmed as equivalent to this one.
- Do not confuse: 0020132764 — PCB of the VMW 236/3-5 according to a spare parts list — Another code; it is not 0020092356.
- To confirm: 0020136649 is sold together with 0020092356, but another sheet lists it for VC/VCW: do not consider it equivalent.
- The plate 0020092356 is listed as Vaillant; none link it to TM-AG2 V132_G2, no official breakdown mentions it, and their boiler lists contradict each other. Boiler registered.
- Pending confirmation of registered applications by model, variant, or programming: Vaillant VMW ES 21/245/4-5 B3.