Vaillant PCB TL-AB PM-03 · 0020013352 · VMW ES 242/3-5 M and VMW ES 242/3-3 M
Refurbished Vaillant Vaillant

Vaillant PCB TL-AB PM-03 · 0020013352 · VMW ES 242/3-5 M and VMW ES 242/3-3 M

Control board or PCB of the Vaillant boiler. It is one of the components to check when the boiler does not ignite, does not respond to the thermostat, or restarts by itself, after checking power supply and connections.

Type of part
Vaillant
Catalogue reference
0020013352
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Vaillant boilers compatible with reference 0020013352

Vaillant with reference 0020013352. A confirmed compatibility: Vaillant VMW ES 242/3-3 M. There are 2 other models that we are still verifying.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW ES 242/3-3 MVaillantContrasted

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Vaillant VMW ES 242/2-5VaillantUnconfirmed
Vaillant VMW ES 242/3-5 MVaillantUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if reference 0020013352 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Check your PCB for the code 0020013352 and compare it with ours. Ours also marks 0020018223 and the circuit TL-AB PM-03.
  2. Check the rating plate to see if your boiler is a Vaillant VMW ES 242/3-5 M or VMW ES 242/3-3 M, both confirmed. The VMW ES 242/2-5 is only mentioned.
  3. To confirm: Do not confuse it with 0020035443 (for the VMW 242/4-5 M R1) nor rely on 00712025, which only appears in a title.
  4. If they match, call us at 911 17 77 77 with your boiler model and we will reserve it for you.
Diagnosis and fault codes

Symptoms that require diagnosis in the Vaillant 0020013352

Common symptoms and faults

  • 01

    The boiler does not ignite or does not respond to any commands from the thermostat.

    Cause: it is mentioned among the signs of needing to change the PCB 0020013352; have it diagnosed by a technician.

  • 02

    Erratic fault codes on the screen or continuous restarts

    Cause: Other two signals associated with the PCB.

  • 03

    Stuck relays or burnt tracks on the circuit

    Cause: Fault that it attributes to the PCB.

  • 04

    No signs of life or screen off after a voltage spike

    Cause: The same seller cites it as the reason for changing the PCB.

  • 05

    The boiler does not ignite: after three attempts without a flame, the fault code F.28 appears and it goes into fault mode.

    Cause: Gas shortage or ignition failure, faulty electrodes or damaged PCB.

    If it repeats, have a technician check it. Do not attempt to reset multiple times in a row.

  • 06

    The boiler shuts down during operation and the restart fails (fault code F.29).

    Cause: Temporary gas cut, gas recirculation, condensates, or faulty grounding.

    Have a technician check it.

  • 07

    The gas valve does not activate: the boiler stops with fault code F.61.

    Cause: Fault in the wiring or in the coils of the gas valve, or faulty PCB.

    Have a technician check it.

Vaillant fault codes that require diagnosis

CodeFaultTechnical checks
F.28Start-up fault: after three attempts without flame, the boiler goes into fault.If it repeats, have a technician check it: it could be the gas, the electrodes, or the PCB.
F.29Flame loss during operation and failed reignition.If it repeats, have a technician check it: it could be the gas supply, the flue gas recirculation, the grounding, or the ignition.
F.61The gas valve does not activate properly: fault in the wiring, coils, or PCB.Have a technician check it. Point to the PCB if the wiring of the gas valve is correct.
F.62The gas valve takes time to close after the flame goes out.Have a technician check it: it could be the gas valve, the electrode, or the PCB.
F.63Fault in the memory of the PCB (EEPROM).It usually points to the PCB: have a technician check it.
F.67The flame signal is not valid: fault in the electronics or ionization.If it goes out when turning on, have a technician check the PCB and the ionization.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Vaillant 0020013352

Catalogue reference
0020013352
Uniclima internal SKU
PLC176
Brand
Vaillant
Type of part
Vaillant
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Inventory — Application indicated in inventory
VMW ES 242/3-5 M
Identification — Marked designation
TL-AB PM-03
Identification — Marked code
0020013352
Identification — Marked code
0020018223
Identification — Marked code
TL-AB PM-03
Inventory data — Application indicated in inventory
VMW ES 242/3-5 M
Pending applications to verify
VMW ES 242/3-5 M — noted compatibility; pending confirmation by variant. Registered application: for your product 10218 (“Vaillant PCB (0020013352)”): turboTEC VMW ES 242/3-5 M; turboTEC VMW ES 202/3-5 M; turboTEC VMW ES 282/3-5 M; turboTEC VMW ES 322/3-5 M; turboTEC VMW ES 362/3-5 M. Pending verification with manufacturer documentation for the reference and physical variant; this commercial statement does not certify compatibility or interchangeability.
Before purchasing
  • They are commercial texts, not an official Vaillant table: they do not provide fault codes for the boiler.
  • To confirm: Vaillant VMW ES 242/2-5 — 1 origin: (its technical sheet and the)
  • Not compatible or excluded: Vaillant VMW 242/4-5 M R1 — with another PCB: 0020035443
  • Do not confuse: 0020035443 — Vaillant PCB that lists for the VMW 242/4-5 M R1 — Another code and another boiler model: ours is brand 0020013352.
  • Do not confuse: 00712025 — Code that appears only in the title of a technical sheet, next to «VMW 242/2-3 R1» — The technical sheet does not explain it and its table gives 0020013352 for the VMW ES 242/3-5 M.
  • Only the 0020013352 part code appears among the three. Also compare the 0020018223 and the TL-AB PM-03 with your PCB.
  • and they connect the 0020013352 to a Vaillant PCB; to a TURBOTEC control panel. Without official breakdown; only the first reference is the VMW ES 242/3-5 M. The title of its technical sheet lists 00712025 for another boiler.
  • Pending registered applications to confirm by model, variant, or programming: Vaillant VMW ES 242/3-5 M.
Frequently Asked Questions

Frequently asked questions: vaillant 0020013352

Where is the code for this PCB and what other markings should I compare?
We do not have data on which area of the PCB the code is printed. Our unit has marked 0020013352, 0020018223, and the circuit TL-AB PM-03; compare them with your PCB. Give 0020013352 as "OEM Reference," and it is linked to a Vaillant PCB and a Vaillant TURBOTEC control panel. Not confirmed: 0020018223 or TL-AB PM-03.
Is it compatible with my Vaillant VMW ES 242/3-5 M or VMW ES 242/3-3 M?
Check the status of each model in the compatibility sections; the pending variants are not validated. Registered: for the VMW ES 242/3-5 M and for the VMW ES 242/3-3 M; additionally, provide the 0020013352 for the 242/3-5 M. We have not located an official breakdown from Vaillant that includes the PCB. Check the model on the rating plate of your boiler.
Is it suitable for the VMW ES 242/2-5 or other VMW boilers?
Check the status of each model in the compatibility sections; the pending variants are not validated. Only mention the VMW ES 242/2-5 with the 0020013352: it is an origin and we do not consider it registered. That list includes the VMW 242/4-5 M R1 with another PCB, the 0020035443. If your model is not the VMW ES 242/3-5 M or the VMW ES 242/3-3 M, send us a photo of your PCB and the rating plate from Contact or call 911 17 77 77.
What is the difference between 0020013352, 0020018223, and TL-AB PM-03?
All three are marked on our part and confirmed. The 0020013352 is the code for the Vaillant PCB and the TL-AB PM-03 is the designation of the circuit. No documentation explains the 0020018223 or the relationship between the three: compare them all with your PCB.
Is it the same PCB as the 0020035443 or the 00712025 that appear in some?
We do not consider it the same. List 0020035443 as the PCB for the VMW 242/4-5 M R1, another boiler model. 00712025 only appears in the title of one of its technical sheets, alongside "VMW 242/2-3 R1", without explanation; the header and the table of that sheet provide 0020013352 for the VMW ES 242/3-5 M.
What symptoms point to this PCB?
A boiler that does not ignite or does not respond to the thermostat, erratic errors on the display, continuous resets, and stuck relays or burnt traces. The same seller adds a boiler with no signs of life or with the display turned off after a voltage spike.
Who should install this PCB and what should be checked beforehand?
A qualified technician does not recommend that inexperienced personnel install it and indicates that a technician should check the input voltages before ruling out other elements.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Vaillant PCB TL-AB PM-03 · 0020013352 · VMW ES 242/3-5 M and VMW ES 242/3-3 M