Thermomanometer For Atmoblock, Turboblock, Thermocompact And Turbomax Boilers

Thermomanometer For Atmoblock, Turboblock, Thermocompact And Turbomax Boilers

Analog thermometer-manometer mounted on the boiler panel, with a dial indicating the water temperature (approximately 0-120 °C) and the circuit pressure (0-4 bar). It allows for a quick check to see if the installation has sufficient pressure to operate. Replacement requires confirming the fault through a technical diagnosis.

Catalogue reference
101558
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Vaillant boilers compatible with reference 101558

Pressure gauge with reference 101558. 13 verified compatibilities: VC 242 E and VCM 242 E.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VC 242 EVC / VCM (Turbo/ThermoCompact)Contrasted
Vaillant VCM 242 EVC / VCM (Turbo/ThermoCompact)Contrasted
Vaillant VCM 182 EVC / VCM (Turbo/ThermoCompact)Contrasted
Vaillant VCM 282 EVC / VCM (Turbo/ThermoCompact)Contrasted
Vaillant VMW 242 EVMW (Turbo/Atmo)Contrasted
Vaillant VMW 282 EVMW (Turbo/Atmo)Contrasted
Vaillant VMW 240VMW (Turbo/Atmo)Contrasted
Vaillant VMW 280VMW (Turbo/Atmo)Contrasted
Vaillant VM 180VMContrasted
Vaillant VM 280VMContrasted
Vaillant VM 240VMContrasted
Vaillant VM 282 EVMContrasted
Vaillant VU 242 EVU (TurboMax/atmoMax)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 101558 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 101558. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the manometer 101558

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure needle always shows the same reading, whether water is added or removed from the circuit.

    Cause: The mechanism of the pressure gauge gets internally stuck and stops moving with the actual pressure changes.

    Fill the system a bit with the filling key and check if the needle reacts before replacing the part.

  • 02

    Water is leaking on the panel, right in the area where the thermometer-manometer is mounted.

    Cause: The connection of the thermometer-manometer to the circuit loses its seal with use, and water leaks through there.

    Locate the exact point of the leak with dry paper before purchasing; it may be coming from a nearby valve and not from the pressure gauge itself.

  • 03

    The water temperature is not clearly visible on the dial, although the pressure can be read normally.

    Cause: The temperature indicator and the pressure indicator share a dial but are independent mechanisms, and one can fail without the other.

    Note if only the temperature needle fails or if the pressure needle does as well; this helps confirm if the entire part is needed.

  • 04

    The glass of the dial is broken or very scratched, and the reading is no longer distinguishable.

    Cause: It is the most exposed part of the component, and a bump during an inspection or cleaning is usually the reason.

    Check that the break is only in the glass and that the needle continues to move as the pressure changes.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Vaillant 101558 pressure gauge datasheet

Catalogue reference
101558
Uniclima internal SKU
MPTVCMES180X
Brand
Vaillant
Type of part
Pressure gauges & aquastats
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Temperature range (dial)
0-120 °C
Pressure range (gauge)
0-4 bar
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure gauge 101558

Is this thermomanometer suitable for an Atmoblock VM 240 X boiler?
Yes, it is indicated for the Atmoblock VM 240, as well as for other models in the VM/VMW range.
When should the thermomanometer of the Atmoblock VMW 242 E be replaced?
The technical diagnosis must confirm that it is necessary to replace it, even when the needle does not indicate correctly, the glass is broken, or there is a leak in the connection to the circuit.
What pressure and temperature range does this manometer indicate on an Atmoblock VM 280?
From 0 to 4 bar of pressure and from 0 to 120°C of temperature approximately, according to the gauge.
Is the MPTVCMES180X manometer compatible with the VCM 242 E boiler?
Yes, it is compatible with the VCM 242 E boiler, which is part of the VC/VCM range.
How many models are compatible with the thermomanometer for Atmoblock and Thermocompact boilers?
This thermomanometer is compatible with a total of 13 models.
What to do if the thermometer does not read correctly?
This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.