Air Pressure Switch 50 PA Chaffoteaux Alixia 24 FF Ref. 65104671 01

Air Pressure Switch 50 PA Chaffoteaux Alixia 24 FF Ref. 65104671 01

Ref. 65104671-01

20 €VAT includedIn stock · 2 units

Pressure switch: refurbished spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Compatible with Alixia 24 FF, Pigma 25 FF, Talia 25 FF (ref. 65104671-01). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
65104671-01
Brand
Chaffoteaux
Type of part
Pressure switches
Available units
2 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 65104671-01) equips these models. Verified compatibility; check the reference before purchasing.

Chaffoteaux Alixia FF

  • Alixia 24 FF

Chaffoteaux Pigma FF

  • Pigma 25 FF

Chaffoteaux Talia FF

  • Talia 25 FF

Ariston Clas FF

  • Clas 24 FF

Ariston Egis FF

  • Egis 24 FF

Ariston Genus FF

  • Genus 24 FF

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
6 07Authorization of the flue pressure switch preceding the ignition sequence.The air pressure switch is closed at rest (stuck contact or tubes incorrectly connected), which is why the PCB detects it before powering the fan; check the continuity of the pressure switch at rest (it should be open) and inspect the position/condition of the tubes.
6 08Lack of authorization from the flue pressure switch with the fan on.With the fan running, the pressure switch does not close because it does not reach the differential (membrane fatigued or connections/tubes obstructed/inverted); check that it closes at ~50 Pa by applying vacuum and measuring continuity during start-up.
6 P1Delay in the authorization of the flue pressure switch.The pressure switch takes time to close (lazy diaphragm or condensate in the tube) and the authorization arrives late; check closing times with a manometer and continuity of the contact when the fan starts.
6 P2Flue Pressure Opening.The pressure switch opens during the cycle (unstable contact or pressure drop), losing the authorization; check continuity under load with the fan active and inspect hoses/venturi for blockages/condensates.
How do I know if this pressure switch is for my boiler?
Verify the reference 65104671-01 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Huba part.
What is it used for?
The pressure switch controls the pressure/draught (of air in sealed systems) or water to authorize operation.
Is the boiler not starting or showing a draught fault?
If the fan spins but does not ignite, check the pressure tubes (loose/blocked), the diaphragm, and the fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the tightness of the pressure pipes and the switching of the contact.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.