Air Pressure Switch Ariston Genus 27 Bffi 571652 01

Air Pressure Switch Ariston Genus 27 Bffi 571652 01

Ref. 571652-01

30 €VAT includedIn stock · 5 units

Pressure switch: refurbished spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Reference 571652-01. Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
571652-01
Brand
Ariston
Type of part
Pressure switches
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
607Flue pressure switch ON with fan OFF (pre-ignition authorization).The air pressure switch indicates closure before the fan starts (contacts stuck, pressure tube pressed/blocked). Check the continuity of the pressure switch and ΔP at the intake/exhaust ports with a differential manometer (~0.47 mbar at maximum power) and inspect the tubes.
608Flue pressure switch OFF with fan ON (does not authorize ignition).With the fan running, the pressure switch does not close due to a damaged diaphragm, blocked tubes, or incorrect adjustment, causing the PCB to lock due to lack of approval. Check the electrical closure of the pressure switch at start-up and ΔP with a differential manometer; inspect the pressure switch hoses.
6P1Air pressure switch delay.The pressure switch takes time to close after the fan starts (dirt/sticking of the micro, leaks in tubes, or insufficient ΔP). Check the closing time and ΔP during start-up with a differential manometer and multimeter.
6P2Air pressure switch opening.During operation, the pressure switch opens (pressure drop) due to partial obstruction in intake/exhaust, leakage in tubes, or a defective pressure switch. Check contact stability and ΔP under load; inspect and replace the pressure switch if it does not maintain state.