| 60-80-90 | Insufficient pressure in the pressure switch or flue thermostat. | The air differential pressure switch does not close with the fan running (lack of depression/obstruction or fatigued diaphragm). Check that the tubes are crossed and clean, the operation of the extractor, and that the microcontact closes by applying slight depression while measuring continuity. |
| 40-50-80-90 | Pressure above zero in the pressure switch or flue thermostat. | The pressure switch appears closed at rest (membrane/micro stuck, tubes inverted or with condensates). Check that the contact is open with the boiler off, clean/dry connections and confirm switching by applying slight pressure/vacuum and measuring continuity. |
| 19 | Pressure above zero in the pressure switch or flue thermostat. | In boards with display (R/RS/Victoria FF family), the pressure switch remains "closed" without demand. Verify that the micro is open at rest, correctly check/invert the pneumatic connections, and rule out water/obstructions in the tubes. |
| 20 | Insufficient pressure in the pressure switch or flue thermostat. | On boards with a display, the pressure switch does not close when the fan starts (lack of draft/obstruction or pressure switch out of adjustment). Check the extractor, flue duct, and electrical closure of the pressure switch when generating depression; inspect crossed tubes and tightness. |