Chaffoteaux Air Pressure Switch MX2 24 FF Huba Control 61313340 01

Chaffoteaux Air Pressure Switch MX2 24 FF Huba Control 61313340 01

Ref. 6131334001

30 €VAT includedIn stock · 3 units

Pressure switch: refurbished spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Compatible with MX2 24 FF, MX2 30 FF, Minima MX2 24 FF (ref. 6131334001). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
6131334001
Brand
Chaffoteaux
Type of part
Pressure switches
Available units
3 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 6131334001) equips these models. Verified compatibility; check the reference before purchasing.

Chaffoteaux MX2 (24 FF)

  • MX2 24 FF
  • MX2 30 FF

Chaffoteaux Minima MX2 (24 FF)

  • Minima MX2 24 FF
  • Minima MX2 24 FF NG

Chaffoteaux Compy MX2 (24 FF)

  • Compy MX2 24 FF

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
40-60-80Extractor activated but the pressure switch does not activate.The flue pressure switch does not close when the fan starts (damaged diaphragm/contacts, blocked tubes/venturi, or insufficient ΔP). Check the continuity of the pressure switch and the depression in the venturi with the fan running; inspect tubes and wiring.
40-60-70Extractor deactivated but the pressure switch does not return to the off position.The pressure switch remains 'stuck' in ON with the fan stopped (contacts seized or pressure tube bypassed), causing the PCB to block the start-up. Check that the micro switch opens at rest, that there is no water/dirt in the tubes, and that it switches when a slight vacuum is applied.
How do I know if this pressure switch is for my boiler?
Verify the reference 6131334001 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part. It is a Huba part.
What is it used for?
The pressure switch controls the pressure/draught (of air in sealed systems) or water to authorize operation.
Is the boiler not starting or showing a draught fault?
If the fan spins but does not ignite, check the pressure tubes (loose/blocked), the diaphragm, and the fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the tightness of the pressure pipes and the switching of the contact.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.
Scroll to the top