Chaffoteaux Niagara Delta 30 FF Air Pressure Switch 61307665 01

Chaffoteaux Niagara Delta 30 FF Air Pressure Switch 61307665 01

Ref. 61307665-01

25 €VAT includedIn stock · 4 units

Pressure switch: reconditioned spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Compatible with Niagara Delta 30 FF (ref. 61307665-01). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
61307665-01
Brand
Chaffoteaux
Type of part
Pressure switches
Available units
4 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 61307665-01) equips these models. Verified compatibility; check the reference before purchasing.

Niagara Delta

  • Niagara Delta 30 FF

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
21Absence of extraction flow (FF).The air pressure switch does not switch even though the extractor is activated (remains at 0) due to lack of depression/obstruction in inlets or a faulty pressure switch; verify by applying depression and measuring NO/NC continuity of the pressure switch and checking tubes/fan.
22Flue extraction detection device fault (FF).Short circuit in the 3-wire air pressure switch (NO/NC closing simultaneously or harness short) detected by the electronics; verify by disconnecting the 3-wire connector and measuring that NO and NC are not closed simultaneously, as well as inspecting wiring and moisture.
How do I know if this pressure switch is for my boiler?
Verify the reference 61307665-01 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The pressure switch controls the pressure/draught (of air in sealed systems) or water to authorize operation.
Is the boiler not starting or showing a draught fault?
If the fan spins but does not ignite, check the pressure tubes (loose/blocked), the diaphragm, and the fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the tightness of the pressure pipes and the switching of the contact.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.