Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
C1The differential pressure switch has been activated during operation.The air pressure switch opens its contact during operation due to a fatigued diaphragm, defective microswitch, or loss of vacuum in the circuit; it is checked by measuring continuity at the pressure switch terminals while the fan is running and inspecting the hoses/Venturi connections.
C4The differential pressure indicator does not open with the fan disconnected.The air pressure switch remains stuck/closed (contacts adhered or false pressure due to incorrectly connected hoses); it is checked by cutting power to the fan and verifying that the pressure switch opens (no continuity), and testing its manual operation with a slight vacuum/pressure.
C6The differential pressure switch does not close.The air pressure switch does not reach switching due to lack of depression (blocked tube/leak) or due to an internal fault of the pressure switch itself; it is checked by measuring continuity during start-up with the fan running and inspecting/probing hoses and pressure inlets.
Scroll to the top