Pressure Switch Baxi Roca Laura 20 20 F Ref. 122450050

Pressure Switch Baxi Roca Laura 20 20 F Ref. 122450050

20 €VAT includedIn stock · 4 units

Pressure switch: reconditioned spare part that controls air or water pressure to authorize operation. Useful if the boiler does not start or shows a draft error. Compatible with Laura 20/20 F, Laura 35/35 F S/A, Laura 35 AF (ref. 122450050). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
122450050
Brand
Baxi Roca
Type of part
Pressure switches
Available units
4 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 122450050) equips these models. Verified compatibility; check the reference before purchasing.

Baxi Roca Laura

  • Laura 20/20 F
  • Laura 35/35 F S/A
  • Laura 35 AF
  • Laura Plus 28/28

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
03Lack of pressure in the heating circuit.If the water pressure switch (122450050) does not close even though the system is >1 bar (membrane/switch faulty or defective connections), the electronics interpret insufficient pressure and lock with 03. Verify by increasing the pressure to 1.2–1.5 bar and measuring the continuity of the pressure switch: it should close under pressure; if not, replace it.
How do I know if this pressure switch is for my boiler?
Verify the reference 122450050 printed and ensure your model is on the list of compatible ones; also compare the connections with the original part.
What is it used for?
The pressure switch controls the pressure/draught (of air in sealed systems) or water to authorize operation.
Is the boiler not starting or showing a draught fault?
If the fan spins but does not ignite, check the pressure tubes (loose/blocked), the diaphragm, and the fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the tightness of the pressure pipes and the switching of the contact.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.

Spare Parts Related Boiler Laura 20 20 F

Scroll to the top