Vaillant Air Pressure Switch VMW ES 24/282/4-5 Ref. 0020041905

Vaillant Air Pressure Switch VMW ES 24/282/4-5 Ref. 0020041905

35 €VAT includedOUT OF STOCK

When you turn on the heating, the air pressure switch Vaillant VMW ES 24/282/4-5 is responsible for monitoring the air pressure and authorizing the operation of the boiler. If this part fails, you will notice that the boiler does not start or gets locked, even if the pressure is correct, and the fault code F.33: Pressure switch failure may appear. This pressure switch is compatible with several models from the Turbotec Plus range, such as the VMW 24/282/4-5 RV and the VMW 21/245/4-5, among others. It is advisable to replace it when you experience these starting or locking issues.

Compatibility

Vaillant boilers compatible with reference 0020041905

Pressure switch with reference 0020041905. 17 confirmed compatibilities: VMW 24/282/4-5 RV and VMW 24/282/4-5 RV R2.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 24/282/4-5 RVTurbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 24/282/4-5 RV R2Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 21/245/4-5Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 21/245/4-5 R3Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 21/245/4-3 R3Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 28/322/4-5 RVTurbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 28/322/4-5 RV R2Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 32/362/3-5 RVTurbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 32/362/3-5 RV R2Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 255/4-7Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 255/4-7 R3Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VM 242/4-5Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VM 242/4-5 R2Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VM 282/4-5Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VM 282/4-5 R2Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 282/4-3 R1Turbotec Plus (VMW/VM ES)Contrasted
Vaillant VMW 282/4-3 R2Turbotec Plus (VMW/VM ES)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020041905 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020041905. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 0020041905 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler starts the fan pre-purge but locks out before igniting the burner.

    Cause: The pressure switch does not close the contact that detects the pressure difference generated by the fan during the pre-purge.

    Make sure that the fan spins freely and at a good speed; if it spins slowly, the pressure switch will not receive enough pressure to switch.

  • 02

    The ignition fault is intermittent: sometimes the boiler starts up properly and other times it stops just after the pre-purge.

    Cause: A limit switch on the pressure switch causes small variations in draft to determine whether the boiler ignites or locks out.

    Check the silicone tubes of the pressure switch to see if they are partially blocked or poorly connected at either end.

  • 03

    After cleaning or handling the flue duct, the boiler started to show an air pressure fault.

    Cause: A small misalignment in the duct can change the back pressure just enough for the pressure switch to stop switching within its range.

    Check again that the flue duct is properly assembled and sealed after handling, before replacing the part.

  • 04

    The fault only appears when cold, right after starting the boiler in the morning, and the rest of the day it works without any issues.

    Cause: The condensation accumulated overnight in the pressure intake pipe can clog it just enough to prevent the first switch of the day.

    Cut off the power for a moment and disconnect the silicone tube from the pressure switch; check that no accumulated water is dripping before declaring the part faulty.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.33Pressure switch fault (the manometric capsule does not activate).The air pressure switch 0020041905 does not change state when the fan starts/stops due to lack of pressure or damaged diaphragm/contacts; check continuity at its terminals during fan start-up and the pressure in the hoses/venturi with a manometer, and inspect for obstructions in the pipes and chimney.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Vaillant 0020041905 pressure switch datasheet

Catalogue reference
0020041905
Brand
Vaillant
Type of part
Pressure switches
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

base code
605.99561
pressure differential (opening/closing)
80/68 Pa
electric charge
1(0.5) A / 250V~
manufacturing batch
UPJEHI
manufacturing date
week 47 of 2008 (47/08)
number marked on the part (does not match the catalog reference)
4000121232
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch 0020041905

Is this pressure switch suitable for a Vaillant VU 202/3-5 R2?
Yes, it is on the list of boilers compatible with this part.
What pressure does this pressure switch open and close the circuit at in the VMW 32/362/3-5?
At 80/68 Pa for opening/closing, according to the label.

Spare parts related to Vaillant Turbotec Plus (VMW/VM ES)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Vaillant Air Pressure Switch VMW ES 24/282/4-5 Ref. 0020041905