Huba Control Air Pressure Switch for Vaillant Turbotec Plus VMW 21/245 - Ref. 0020041905
Differential air pressure switch manufactured by Huba Control, code 605.99880, for Vaillant Turbotec Plus VMW boilers. It switches at a differential pressure of opening/closing of 85/70 Pa, with a maximum electrical load of 0.2(0.1)A at 30V~ and supports up to 1500 Pa of maximum allowable pressure. Replacement requires first confirming the fault of the part through technical diagnosis, even when the switching fails and the boiler does not complete the ignition.
- Type of part
- Pressure switches
- Status
- Refurbished
- Catalogue reference
- 0020041905
- Warranty
- 1 year
Vaillant boilers compatible with reference 0020041905
Pressure switch with reference 0020041905. 17 confirmed compatibilities: VMW 24/282/4-5 RV and VMW 24/282/4-5 RV R2.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant VMW 24/282/4-5 RV | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 24/282/4-5 RV R2 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 21/245/4-5 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 21/245/4-5 R3 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 21/245/4-3 R3 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 28/322/4-5 RV | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 28/322/4-5 RV R2 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 32/362/3-5 RV | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 32/362/3-5 RV R2 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 255/4-7 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 255/4-7 R3 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VM 242/4-5 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VM 242/4-5 R2 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VM 282/4-5 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VM 282/4-5 R2 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 282/4-3 R1 | Turbotec Plus (VMW/VM ES) | Contrasted |
| Vaillant VMW 282/4-3 R2 | Turbotec Plus (VMW/VM ES) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 0020041905 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0020041905. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the pressure switch 0020041905
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite, stops after a few seconds, and needs to be reset to attempt again.
Cause: The pressure switch does not close the switching contact, and the control board interprets that there is not enough air pressure, cutting off the gas for safety.
Check that the extractor is spinning normally and that both silicone tubes of the pressure switch are properly connected and not crushed.
- 02
The display shows a fault warning for the air pressure switch, and in some cases, a lock code also appears on the control.
Cause: It is the signal emitted by the control board when the pressure switch does not confirm the expected pressure differential during the ignition cycle.
Before replacing the part, check the flue for possible blockages and clean the condensate siphon if the boiler is a condensing type.
- 03
After a long period of not being used, like after the summer, the boiler started to show this fault repeatedly.
Cause: With the boiler off, the silicone tube may have come loose slightly or accumulated dirt, leaving the pressure switch without the pressure it needs.
Visually check that the pipes are properly fitted at both ends, both at the pressure switch and at the air collector.
- 04
The fault is intermittent and seems to depend on the wind or the orientation of the flue outlet.
Cause: This pressure switch operates with a narrow switching margin, so external back pressure can push it out of its range.
Note if the fault occurs on windy days; if so, check the external flue terminal before replacing the pressure switch.
Vaillant fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F.33 | Pressure switch fault (the manometric capsule does not activate). | The air pressure switch 0020041905 does not change state when the fan starts/stops due to lack of pressure or damaged diaphragm/contacts; check continuity at its terminals during fan start-up and the pressure in the hoses/venturi with a manometer, and inspect for obstructions in the pipes and chimney. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Vaillant 0020041905 pressure switch datasheet
- Catalogue reference
- 0020041905
- Uniclima internal SKU
- PCVTT21/245
- Brand
- Vaillant
- Type of part
- Pressure switches
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Manufacturer
- Huba Control
- Manufacturer code
- 605.99880
- Pressure differential (open/close)
- 85/70 Pa
- Electric charge
- 0.2(0.1)A / 30V~
- Maximum allowable pressure
- 1500 Pa
- CE marking / notified body
- CE 0085 22
- The electrical rating of this pressure switch (0.2(0.1)A/30V~) is different from other Huba Control pressure switches in the 605.XXXXX series from the same batch (1(0.5)A/250V~, see datasheet PRS2424F); do not confuse references.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Vaillant VMW 21/245/4-5 manual (PDF) Document © Vaillant, provided as a technical reference.