Fagor Air Pressure Switch CE 20E 1N Ref. MU1289600

Fagor Air Pressure Switch CE 20E 1N Ref. MU1289600

Stock · 5 units

The Fagor CE 20E boilers use the Fagor CE 20E 1N air pressure switch, which is responsible for monitoring the air or water pressure and authorizing the operation of the boiler. If this part fails, the boiler may not start or may lock out, even if the actual pressure is correct, displaying the fault code F2: Lockout due to air pressure switch. This pressure switch is compatible with models such as CE 20E 1N, CE 20E 1 GLP, and several from the FEB 20E series, among others. It is recommended to replace it when starting or locking issues occur in the boiler.

VAT included

Compatibility

Fagor boilers compatible with reference MU1289600

Pressure switch with reference MU1289600. Nine confirmed compatibilities: CE 20E 1N and CE 20E 1 GLP.

Proven compatibility

Boiler modelFamilyVerification
Fagor CE 20E 1NFagor CE 20E (Contract / series CE20E)Contrasted
Fagor CE 20E 1 LPGFagor CE 20E (Contract / series CE20E)Contrasted
Fagor FEB 20E 1NFagor FEB 20E (Ecoplus / FEB20E series)Contrasted
Fagor FEB 20E 1GFagor FEB 20E (Ecoplus / FEB20E series)Contrasted
Fagor FEB 20E F 1NFagor FEB 20E (Ecoplus / FEB20E series)Contrasted
Fagor FEB 20E F 1GLPFagor FEB 20E (Ecoplus / FEB20E series)Contrasted
Fagor FEB 20E H 1NFagor FEB 20E (Ecoplus / FEB20E series)Contrasted
Fagor FEB 20E UK 1NFagor FEB 20E (Ecoplus / FEB20E series)Contrasted
Fagor FEB 20E UK 1PRFagor FEB 20E (Ecoplus / FEB20E series)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. MU1289600 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MU1289600. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch MU1289600 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The extractor works, but the burner does not ignite.

    Cause: The pressure switch does not close the contact to allow the flow of gas because it does not detect the correct air pressure.

    Check that the silicone tube on the extractor is properly placed at both ends and without cracks.

  • 02

    The boiler locks up with the fan on, without sparking.

    Cause: This occurs when the pressure switch does not validate the draft within the time that the control board expects before attempting to ignite.

    Check the air intake filter or grille, if the boiler has one: a dirty intake prevents reaching the minimum pressure.

  • 03

    The startup fault is not constant: sometimes it ignites properly and other times it gets stuck.

    Cause: A faulty contact does not switch at the same pressure point every time, so the result varies with each attempt.

    Clean and check the electrical connections of the pressure switch before replacing it: a poor connection in the wiring can cause similar symptoms.

  • 04

    The fault occurs mainly with strong winds or bad weather.

    Cause: Wind can affect the pressure that the pressure switch needs to read in order to close the contact in installations with exposed flue gas outlets.

    Note if the fault coincides with windy days: if so, check the flue gas outlet and its protection before replacing the part.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F2Air pressure switch lockout: correct circulation/status of the pressure switch not detected at start-up.The air pressure switch does not change state (internal defect, blocked tubes, or reversed connections), so the PCB detects a lack of draft; check continuity COM-NO with the fan running and inspect/vacuum the pressure intake and hoses.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Fagor MU1289600 pressure switch datasheet

Catalogue reference
MU1289600
Brand
Fagor
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

base code
605.99613
switching threshold (opening/closing)
120/80 Pa
electric charge
0.2(0.1) A / 30V~
batch
JIMBID
brand and date printed on the part
FAGOR 05/03
part number (main reading)
N49G003M1
part number (alternative reading, verify)
N496003M1
Frequently Asked Questions

Frequently asked questions about the pressure switch MU1289600

Is this pressure switch suitable for the Fagor FEB20EH1N?
Yes, it is on the list of compatible boilers along with the CE20E1N, CE20E1GLP, and other FEB20E versions.
What fault does replacing the pressure switch of the Fagor CE20E1N resolve?
Detect the pressure generated by the fan to validate the draft before ignition; it is replaced when that detection fails.
What electrical load does the pressure switch MU1289600 of the Fagor CE20E1N support?
0.2(0.1) A at 30V~, according to the label.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Fagor Air Pressure Switch CE 20E 1N Ref. MU1289600