Fagor FEB23E1B Air Pressure Switch - Huba Control 605.99667
Air pressure switch manufactured by Huba Control (series 605), installed in Fagor boilers ECOCOMPACFE20E, FE24EC1N, and FEB23E1B. It cuts off ignition if it does not detect the correct flue draft. It is identified by the code Huba 605.99667, equivalent to the Fagor code N49G006M4. It is replaced when the boiler does not ignite or is blocked due to an air pressure fault.
VAT included
Consult via WhatsAppFagor boilers compatible with reference N49G006M4
Pressure switch with reference N49G006M4. Six confirmed compatibilities: FE-24E/1 B and FE-24E/1 N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE-24E/1 B | Fagor FE (Super Compact) | Contrasted |
| Fagor FE-24E/1 N | Fagor FE (Super Compact) | Contrasted |
| Fagor FE-24EC-1N | Fagor FE (Super Compact) | Contrasted |
| Fagor FEB-23E/1 B | Fagor FEB | Contrasted |
| Fagor FEE-24MA/1 N | Fagor FEE | Contrasted |
| Fagor ECO COMPAC FE20E | Fagor Eco Compact | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. N49G006M4 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference N49G006M4. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch N49G006M4 resolves.
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite: it stays in standby or tries to ignite without the flame appearing.
Cause: The air pressure switch does not close the contact because it does not detect the minimum draft depression, and without that signal, the control board does not allow the gas to open.
Make sure that the extractor starts and spins correctly before assuming that the pressure switch is faulty.
- 02
The boiler intermittently locks out: sometimes it starts up properly and other times it stops when trying to start.
Cause: A partially obstructed pressure port causes the pressure switch to receive an irregular signal and operate inconsistently.
Check the pressure connections and the silicone tubes of the pressure switch: make sure they are free of condensation, folds, or dirt.
- 03
The extractor works well but the burner never ignites.
Cause: Even if the fan is running, if the pressure switch does not close the contact, the control board understands that there is not enough draft and does not allow the gas to pass.
Check that the pressure switch activates when the fan starts (you usually hear a small click); if it doesn't activate, first check its tubes before the part itself.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F-2 | The air pressure switch does not detect air circulation (or is defective) and the boiler locks out. | The air pressure switch does not close due to lack of depression/draught or internal fault; check continuity of the contact when the fan starts and measure depression in the tubes, as well as inspect for obstructions in intake/exhaust. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for the Fagor pressure switch N49G006M4
- Catalogue reference
- N49G006M4
- Brand
- Fagor
- Type of part
- Pressure switches
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- switching pressure
- 140/89 Pa
- regulation/setting range
- 0.2(0.1)/30~
- factory code (Huba Control)
- 605.99667
- batch
- YWDBHH
- Fagor reference
- N49G006M4