Air Pressure Switch 605.99478 For Fagor FE 24AE 1N - Ref. MU0500112

Air Pressure Switch 605.99478 For Fagor FE 24AE 1N - Ref. MU0500112

Stock · 5 units

Air Pressure Switch 605.99478 for Fagor FE 24AE 1N - Ref. MU0500112. This part checks the air pressure and allows the boiler to operate correctly. If it fails, you will notice that the boiler does not start or gets locked, which may generate the fault code F-2: the air pressure switch does not detect air circulation or is faulty. It is compatible with models such as Fagor FE 24 E, FE 24 AE, and ECOCOMPACT FE 20 E, among others. It should be replaced when it shows faults in pressure detection or prevents the boiler from starting.

VAT included

Compatibility

Fagor boilers compatible with reference MU0500112

Pressure switch with reference MU0500112. Six confirmed compatibilities: FE24E/1B and FE24E/1N.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE24E/1BFagor Super Compact FE 24 E / FE 24 AEContrasted
Fagor FE24E/1NFagor Super Compact FE 24 E / FE 24 AEContrasted
Fagor FE24EC1NFagor Super Compact FE 24 E / FE 24 AEContrasted
Fagor FE24AE/1NFagor Super Compact FE 24 E / FE 24 AEContrasted
Fagor ECOCOMPACT FE20EFagor ECOCOMPACT FE 20 EContrasted
Fagor FEB23E1BFagor FEB 23 EContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. MU0500112 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MU0500112. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch MU0500112 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite several times and locks out with the fan running.

    Cause: The pressure switch does not close the contact even though the fan is working, so the control board does not allow the gas to flow.

    Before changing it, check that the silicone pressure intake tube is not bent, broken, or disconnected from the fan.

  • 02

    The problem occurs especially with strong winds or intense cold.

    Cause: Air currents in the flue gas outlet can prevent the pressure switch from reaching the necessary pressure differential to operate.

    Check the flue terminal outside: if it is blocked, bent, or too exposed to the wind, correct that before considering replacing the part.

  • 03

    The pressure switch clicks, but the boiler still locks out.

    Cause: It may switch mechanically and still not close the electrical contact properly if the terminals are dirty or oxidized.

    With the boiler disconnected, use a multimeter to check that the pressure switch shows continuity when pressure is applied manually.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F-2The air pressure switch does not detect air circulation or is faulty (lockout).The air pressure switch MU0500112 does not switch when the fan starts due to an internal fault or incorrect +/− connections; check the continuity of contacts while the fan starts and apply vacuum to the connections, and inspect hoses and polarity.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Fagor MU0500112 pressure switch datasheet

Catalogue reference
MU0500112
Brand
Fagor
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer code
605.99478
Switching pressure
89/74 Pa
Electrical feature
0,2(0,1)/30~
Frequently Asked Questions

Frequently asked questions about the pressure switch MU0500112

Is this pressure switch of the FE 24AE 1N for air or water?
Air. The switching pressure is in pascals (89/74 Pa), typical of combustion pressure switches.
At what pressure does the pressure switch of the Fagor FE 24AE 1N switch?
89/74 Pa.
When should this air pressure switch be replaced in the Fagor FE 24AE 1N?
When it does not switch or the boiler gets stuck in pre-purge.

Spare parts related to Fagor Fagor Super Compact FE 24 E / FE 24 AE

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Air Pressure Switch 605.99478 For Fagor FE 24AE 1N - Ref. MU0500112