Fagor FE 11DL N smoke pressure switch Geyser Gastech Ref. 810006759
Differential pressure switch that Fagor installs in its FE 11DL range and related models. The component is printed with the code 605.09708 and the Geyser Gastech brand, and is set to 150/115 Pa. It cuts off or enables the operation of the burner according to the pressure it detects in the flue gas circuit. It is replaced when it stops switching and the boiler locks out or does not start.
VAT included
Consult via WhatsAppFagor boilers compatible with reference 810006759
Pressure switch with reference 810006759. Five confirmed compatibilities: FE-11DL1B and FE11D1N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE-11DL1B | Fagor FE (water heaters) | Contrasted |
| Fagor FE11D1N | Fagor FE (water heaters) | Contrasted |
| Fagor FE11DPL1B | Fagor FE (water heaters) | Contrasted |
| Fagor FEC11TD1N | Fagor FEC (water heaters) | Contrasted |
| Fagor AQUAPRO-11E1N | Fagor AQUAPRO (water heaters) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 810006759 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 810006759. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch 810006759 resolves.
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and shows an error related to the flue pressure.
Cause: The flue pressure switch does not detect that the gas evacuation is correct, so the control board prevents the burner from igniting.
Check that the flue outlet and the external hood are free of obstructions.
- 02
The fan works, but the burner does not ignite.
Cause: This indicates that the pressure switch does not close the contact even though the fan generates enough pressure.
Measure the electrical continuity of the pressure switch with a multimeter while the fan is running.
- 03
The boiler turns on and off by itself several times in a row.
Cause: An unstable pressure switch causes the control unit to repeatedly validate and invalidate the flue signal.
Check if the shutdown always occurs at the same point in the ignition sequence before considering the part as faulty.
- 04
The ignition fault is not constant: sometimes it starts and sometimes it doesn't.
Cause: The internal contacts of the pressure switch may be oxidized or the diaphragm aged, causing irregular operation.
Remove the pressure switch and visually inspect the condition of the connection tubes and contacts before replacing it.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F2 | Fault in air circulation detection by the flue/air pressure switch. | The flue pressure switch (810006759) does not switch because there is insufficient depression or it is faulty; the PCB does not validate the draft and locks. Check with a differential manometer and inspect the pressure switch tubes, fan, and flue duct; for a specific test, check with a temporary bypass of the pressure switch (diagnostic only). |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for pressure switch Fagor 810006759
- Catalogue reference
- 810006759
- Brand
- Fagor
- Type of part
- Pressure switches
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component code
- 605.09708
- Set pressure
- 150/115 Pa
- Pressure range
- 0,2 (0,1) / 30
- Additional code
- RAH0H8