Air Pressure Switch Boiler Fagor FE24E1N / FE24EC1N - Ref. N49G006M4

Air Pressure Switch Boiler Fagor FE24E1N / FE24EC1N - Ref. N49G006M4

Stock · 4 units

Air pressure switch for Fagor boilers from the FE24E1N, FE24EC1N, ECOCOMPACFE20E, and FEB23E1B series. It monitors the air pressure in the combustion circuit and allows ignition only if the fan is extracting properly. It is replaced when the boiler does not start or shows a ventilation/draft error. Component code 605.99667, differential 140/89 Pa, part reference N49G006M4.

VAT included

Compatibility

Fagor boilers compatible with reference N49G006M4

Pressure switch with reference N49G006M4. Six confirmed compatibilities: FE-24E/1 B and FE-24E/1 N.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE-24E/1 BFagor FE (Super Compact)Contrasted
Fagor FE-24E/1 NFagor FE (Super Compact)Contrasted
Fagor FE-24EC-1NFagor FE (Super Compact)Contrasted
Fagor FEB-23E/1 BFagor FEBContrasted
Fagor FEE-24MA/1 NFagor FEEContrasted
Fagor ECO COMPAC FE20EFagor Eco CompactContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. N49G006M4 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference N49G006M4. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch N49G006M4 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, the fan starts, but it stops before the flame appears.

    Cause: The pressure switch does not close the air contact, so the control board does not command the gas valve to open.

    Check that the silicone tubes between the pressure switch and the fan are not bent, loose, or have accumulated condensation.

  • 02

    The display shows a warning of ventilation failure or lack of draft when starting.

    Cause: This code is displayed when the control board does not receive the pressure signal it expects from the pressure switch, regardless of whether the fan is functioning properly.

    Before changing the part, check the flue and the air intake for any external obstructions (nests, dirt, blocked terminal).

  • 03

    The fan is working properly, but the burner never ignites.

    Cause: If the pressure switch has a stuck contact or a damaged diaphragm, it does not send the signal even if the actual depression is correct.

    Listen to see if the fan maintains stable revolutions for several seconds before considering that the pressure switch is faulty.

  • 04

    The boiler occasionally locks out with the same fault, without a fixed pattern.

    Cause: A worn contact of the pressure switch can work well sometimes and not at other times, causing intermittent faults.

    Note if the blockage coincides with strong wind or heavy rain: this may indicate a problem in the flue section rather than with the pressure switch.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F-2The air pressure switch does not detect air circulation (or is defective) and the boiler locks out.The air pressure switch does not close due to lack of depression/draught or internal fault; check continuity of the contact when the fan starts and measure depression in the tubes, as well as inspect for obstructions in intake/exhaust.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for the Fagor pressure switch N49G006M4

Catalogue reference
N49G006M4
Brand
Fagor
Type of part
Pressure switches
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component code
605.99667
Switching pressure (open/close)
140/89 Pa
Electrical characteristics of the contact
0.2(0.1) A / 30 V~
Batch code
0GUDDG
Brand printed on the disc
FAGOR
Part reference
N49G006M4
Frequently Asked Questions

Frequently asked questions about the pressure switch N49G006M4

Does this pressure switch N49G006M4 work for the Fagor FEB23E1B in addition to the FE24E1N?
Yes, the catalog associates it with ECOCOMPACFE20E, FE24E1N, FE24EC1N, and FEB23E1B.
At what pressure does the pressure switch of the Fagor FE24E1N switch?
Between 140 and 89 Pa depending on whether it opens or closes, with component code 605.99667.
What fault does replacing this pressure switch in the FE24E1N resolve?
It is replaced when the boiler does not start or shows a ventilation or flue error due to not detecting the correct pressure of the extractor.

Spare parts related to Fagor Fagor FE (Super Compact)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Air Pressure Switch Boiler Fagor FE24E1N / FE24EC1N - Ref. N49G006M4