Pressure switch Fagor 605.99842 For FE-24/FEB-24AR

Pressure switch Fagor 605.99842 For FE-24/FEB-24AR

Stock · 4 units

Pressure switch with the FAGOR brand printed on the label, code 605.99842 and secondary code N49G016M0. It detects a switching pressure of 120/100 Pa. It is installed in Fagor boilers of the FE-24 and FEB-24AR series (1FE24TC1N, FE-24NOX, FE-24TC, FEB-24AR). It is replaced when it stops switching correctly and causes ignition failure or lockout.

VAT included

Compatibility

Fagor boilers compatible with reference AS0003109

Pressure switch with reference AS0003109. Four confirmed compatibilities: FE-24NOX/1B and FE 24 NOX/1B.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE-24NOX/1BFagor FE NOXContrasted
Fagor FE 24 NOx/1BFagor FE NOXContrasted
Fagor FEB 24AR/1 NFagor Ecomini FEB ARContrasted
Fagor Ecomini FEB 24ARFagor Ecomini FEB ARContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. AS0003109 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference AS0003109. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch AS0003109 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, the fan sounds, but it shuts off immediately without sparking.

    Cause: The pressure switch does not close the contact that allows ignition because it does not detect sufficient air pressure drop.

    Check that the extractor does not drag or make bearing noise before inspecting the pressure switch.

  • 02

    A fault indicator for air or flue appears as soon as the boiler is turned on.

    Cause: A pressure switch that does not return to its resting position between cycles can cause a false start fault.

    Check that the silicone tube is not punctured or disconnected from the fitting in the area of the extractor.

  • 03

    The boiler works well for a while and then starts to fail more often until it completely stops igniting.

    Cause: The progressive wear of the pressure switch makes it harder to reach the switching point.

    Keep track of when it starts to fail and how often: if it worsens over time, focus more on the pressure switch than on a loose tube.

  • 04

    The extractor has been cleaned and it still won't start, or it starts and stops just like before.

    Cause: If after cleaning the extractor the fault persists, it is common for the pressure switch itself not to be switching.

    Before changing it, ask a technician to measure the actual depression of the extractor with a manometer to confirm that the pressure switch does not reach its cut-off point.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F02Flue/air evacuation fault (the unit does not confirm draft).The differential pressure switch (AS0003109) does not switch because it does not reach the fan's depression or is faulty; the PCB does not receive the 'draft OK' signal and locks in F02. Check with a vacuum gauge/manometer at the ports and measure continuity at the pressure switch terminals during startup, as well as inspect the tubes and Venturi.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Fagor AS0003109 pressure switch datasheet

Catalogue reference
AS0003109
Brand
Fagor
Type of part
Pressure switches
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Fagor (printed as FAGOR on the label)
Part code
605.99842
Switching pressure
120/100 Pa
Secondary code
N49G016M0
Frequently Asked Questions

Frequently asked questions about the pressure switch AS0003109

Is this pressure switch for the FEB-24AR an original part from Fagor?
Yes, the label is printed with FAGOR.
For which models is the pressure switch Fagor 605.99842 compatible?
It is compatible with the models FE-24NOX/1B, FE 24 NOX/1B, FEB 24AR/1 N, and Ecomini FEB 24AR.
What fault can a defective pressure switch cause in the Fagor FEB-24AR?
It can cause ignition failure or boiler lockout when the pressure switch stops switching correctly.
At what pressure does the pressure switch of the Fagor FE-24NOX switch?
Switches to 120/100 Pa, according to the label.
What is the reference for this pressure switch?
The reference is PCFEFEB24.
What fault code is documented for this pressure switch?
The documented fault code is F02.

Spare parts related to Fagor Fagor FE NOX

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Pressure switch Fagor 605.99842 For FE-24/FEB-24AR