Pressure Switch For Flexicom Boilers, British Gas BG330+ And Ultimate 24H - Code 605.99613

Pressure Switch For Flexicom Boilers, British Gas BG330+ And Ultimate 24H - Code 605.99613

Stock · 1 unit

If your boiler does not start or gets blocked, the problem may be with the pressure switch for Flexicom boilers, British Gas BG330+ and Ultimate 24H - Code 605.99613. This component checks the air pressure and ensures that the system operates correctly. When it fails, it can lead to error 1: air pressure switch fault, indicating that circulation is not detected. It is compatible with models such as the Fagor Ecoplus FEB-20E, among others. It is recommended to replace it if the boiler shows these symptoms or if a malfunction is detected in the pressure system.

VAT included

Compatibility

Fagor boilers compatible with reference 0020020716

Pressure switch with reference 0020020716. A proven compatibility: FEB-20E.

Proven compatibility

Boiler modelFamilyVerification
Fagor FEB-20EFagor EcoplusContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020020716 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020020716. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 0020020716 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to start, the fan spins, but it locks out before the flame ignites.

    Cause: The pressure switch does not detect the sufficient depression in the flue duct and does not send the signal for a clear path to the control board.

    Check that the flue duct is not blocked, crushed, or has too many meters or bends for the intended draft of the boiler.

  • 02

    The display shows a fault code related to the pressure switch or the flue gas extraction.

    Cause: The control board interprets that the pressure switch has not changed state within the expected time and aborts the ignition cycle for safety.

    Check that the silicone tubes connecting the pressure switch to the venturi or the extractor are not perforated, sagging, or have accumulated condensation.

  • 03

    The boiler shuts down by itself a few seconds after starting, although the burner does ignite.

    Cause: If the pressure switch contact opens during operation due to a pressure fluctuation, the control board cuts off the gas even if the cycle has already started.

    Check that the fan rotates freely and at a stable speed, without noise or stalling, before considering the pressure switch defective.

  • 04

    The fault mainly occurs with strong winds or depending on the position of the flue gas outlet terminal.

    Cause: This type of pressure switch operates with a narrow pressure range, and a poorly oriented flue can cause the reading to go out of range without the part being faulty.

    Check the flue terminal: it should not be blocked, oriented against the prevailing wind, or shared with another duct.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
1Air pressure switch fault (circulation/draught not detected).The air differential pressure switch does not switch due to a lack of depression in the flue circuit (crossed tubes/obstruction of the venturi or chimney) or due to a fault in the pressure switch itself; check continuity of the contact with the fan running and inspect hoses/venturi/flow.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Fagor pressure switch 0020020716

Catalogue reference
0020020716
Brand
Fagor
Type of part
Pressure switches
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Factory code
605.99613
Setpoint (switching pressure)
120/80 Pa
Parameter printed without interpretation
0.2(0.1)/30~
Printed marking (date)
FAGOR 08/04
Code printed on the part
N49G003M1
Batch
IXYDFE
Frequently Asked Questions

Frequently asked questions about the pressure switch 0020020716

Is this pressure switch suitable for the British Gas BG330+?
Yes, it is on the list of compatible boilers.
What is the setting of the pressure switch for the Flexicom range?
120/80 Pa, according to the label.
When should this pressure switch be checked in the Ultimate 24H?
When the boiler locks out or the burner does not ignite.

Spare parts related to Fagor Fagor Ecoplus

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Pressure Switch For Flexicom Boilers, British Gas BG330+ And Ultimate 24H - Code 605.99613