Fagor Contract CA 20EN Grundfos Circulating Pump Ref. MU1250200
RefurbishedFagorPumpsGrundfos

Fagor Contract CA 20EN Grundfos Circulating Pump Ref. MU1250200

Stock · 3 units

Grundfos circulating pump (Type UPS 15-50 130) mounted in Fagor Contract CA-20 N boilers and models of the same range. It circulates the water in the heating circuit at three selectable speeds. It is replaced when the water does not circulate, makes noise, leaks from the seal, or the rotor is blocked. Power supply 230V~ 50Hz, IP44, up to 10 bar.

VAT included

Compatibility

Fagor boilers compatible with reference N47G000M1

Circulating pump with reference N47G000M1. 12 verified compatibilities: FEB-20E and FEB-20E/1.

Proven compatibility

Boiler modelFamilyVerification
Fagor FEB-20EEco Plus (FEB)Contrasted
Fagor FEB-20E/1Eco Plus (FEB)Contrasted
Fagor FE-20EEco Compact / FE (FE)Contrasted
Fagor FE-20E/1Eco Compact / FE (FE)Contrasted
Fagor CE-20EContract (CE)Contrasted
Fagor CE-20E/1Contract (CE)Contrasted
Fagor FA-20FAContrasted
Fagor FA-20 NFAContrasted
Fagor CA-20CAContrasted
Fagor CA-20 NCAContrasted
Fagor FEE-20FEEContrasted
Fagor FEE-20/1FEEContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. N47G000M1 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference N47G000M1. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulation pump N47G000M1 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The radiators are cold even though the boiler turns on and heats.

    Cause: The pump does not move enough water through the circuit, even though the burner is working well.

    Increase the pump to the highest speed of the three it has before declaring it faulty.

  • 02

    A buzzing or rubbing noise can be heard in the area of the pump.

    Cause: The rotor spins with resistance due to accumulated scale or trapped air in the circuit.

    Bleed the circuit using the nearest bleed valve and check if the noise subsides before replacing it.

  • 03

    Water is dripping from the shaft seal.

    Cause: The mechanical seal has lost its tightness over time.

    Dry the area and check after a few hours of operation if it starts to leak again right at the shaft before purchasing the part.

  • 04

    The pump does not start and the rotor does not turn even by hand.

    Cause: The rotor is jammed due to sediment, which is common after periods of inactivity.

    With the cold installation, try to free the shaft through the front slot before replacing the entire pump.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Fagor N47G000M1 circulation pump.

Catalogue reference
N47G000M1
Brand
Fagor
Type of part
Pumps
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

manufacturer
Grundfos
Fagor reference
MU1250200
Grundfos PN code
59505401
type
UPS 15-50 130
Production code PC
0122FG
voltage
230V~
frequency
50Hz
capacitor
2µF
IP rating
IP44
Thermal class
TF110 / Class F
Maximum pressure
10 bar
Speed 1
0.15A / 35W
Speed 2
0.24A / 60W (a reading from the same label showed 80W, see notices)
Speed 3
0.34A / 85W
Frequently Asked Questions

Frequently asked questions about the circulator pump N47G000M1

Is the pump of the Fagor Contract CA-20 N an original Grundfos?
Yes, the label features the Grundfos logo and text, although it is supplied with the Fagor code MU1250200.
For which Fagor Contract boilers is this circulation pump compatible?
It is compatible with the models from the Eco Plus (FEB), Eco Compact / FE (FE), Contract (CE), FA, CA, and FEE ranges, totaling 12 confirmed models.
What working speeds does the Fagor Contract CA-20 N circulator pump have?
It has three selectable speeds, with power ratings of 35W, between 60-80W, and 85W at 230V~ 50Hz.
What is the maximum pressure that the pump of the Fagor Contract CA-20 N can withstand?
The pump supports up to 10 bar, according to its label.
What is the reference for this circulator pump?
The reference for the pump is BCCA20EN.
Are there documented fault codes for this pump?
No, there are no documented fault codes for this product.