Wilo Circulating Pump for Fagor FE-24 NOx / FE-24 TC / FE-26 TC - Ref. MSL12/6-3 C
Circulating pump manufactured by Wilo, model MSL12/6-3 C, installed in Fagor boilers from the FE-24 and FE-26 range, NOX and TC. It operates at 230V-50Hz, insulation class H, PN6, with three speeds (39, 59, and 80 W). It is replaced when it stops circulating water, makes noise, or does not start. The reference field on its own label is blank.
VAT included
Consult via WhatsAppFagor boilers compatible with reference AS0008269
Circulating pump with reference AS0008269. Two confirmed compatibilities: FE 24 NOX and FE 24 NOX-1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE 24 NOx | Fagor FE NOX | Contrasted |
| Fagor FE 24 NOx-1 | Fagor FE NOX | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference AS0008269 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference AS0008269. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulator pump AS0008269 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler ignites, the burner works, but the radiators do not heat up.
Cause: The circulator does not move water through the heating circuit even though the burner is working.
Check if the pump body vibrates or hums without the shaft rotating.
- 02
The pump does not start.
Cause: The rotor may be blocked by scale or rust, something common after a long shutdown in summer.
With the boiler unplugged, try to unlock the shaft with the front screw before replacing the part.
- 03
Noise or vibration in the circulator while operating.
Cause: It could be due to trapped air in the circuit or a rotor that is rubbing unevenly.
Bleed the radiators and the pump bleeder, and check the pressure of the system.
- 04
Water leak in the body or shaft of the pump.
Cause: The mechanical seal of the shaft has worn out and is not sealing properly.
Dry the area and check when cold if the dripping reappears after a while in operation.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor AS0008269 circulation pump.
- Catalogue reference
- AS0008269
- Brand
- Fagor
- Type of part
- Pumps
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Voltage and frequency
- ~230V-50Hz
- Insulation class
- Class H
- Nominal pressure
- PN6
- Protection rating
- IP44
- Condenser
- 2µF
- Speed I (current/power)
- 0.18 A / 39 W
- Speed II (current/power)
- 0.27 A / 59 W
- Speed III (current/power)
- 0.35 A / 80 W
- Wilo type code
- MSL12/6-3 C
- Number (N°) Wilo
- 4521673