Saunier Duval Themafast F 25 E H Air Pressure Switch MOD Ref. S5744100

Saunier Duval Themafast F 25 E H Air Pressure Switch MOD Ref. S5744100

30 €VAT includedOUT OF STOCK

In the Saunier Duval Themafast boilers, the air pressure switch Themafast F 25 E H MOD controls the air pressure and allows the boiler to operate correctly. If this part fails, the boiler may not start or may lock out, even if the actual pressure is adequate, displaying fault code 02: Air flow safety. This pressure switch is compatible with several models such as the F 25 E H-MOD, F 30 E, and others from the Themafast range, among others. Replacement is carried out when starting failures or operational lockouts occur.

Compatibility

Saunier Duval boilers compatible with reference S5744100

Pressure switch with reference S5744100. 21 verified compatibilities: F 30 E H-MOD and F 35 E1.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 30 E H-MODIsofastContrasted
Saunier Duval F 35 E1IsofastContrasted
Saunier Duval F 35 E H-MODIsofastContrasted
Saunier Duval F 28 E2IsomaxContrasted
Saunier Duval F 28 EAIsotwinContrasted
Saunier Duval F 30 E H-MODIsotwinContrasted
Saunier Duval F 30 EIsosplitContrasted
Saunier Duval F 35 EIsosplitContrasted
Saunier Duval F 35 E H-MODIsosplitContrasted
Saunier Duval F 25 EThemafastContrasted
Saunier Duval F 25 E H-MODThemafastContrasted
Saunier Duval F 30 EThemafastContrasted
Saunier Duval F 30 E H-MODThemafastContrasted
Saunier Duval F 25 EThemaContrasted
Saunier Duval F 25 E STLThemaContrasted
Saunier Duval F AS 25 EThemaContrasted
Saunier Duval F 25 EThemaplusContrasted
Saunier Duval F 30 EThemaplusContrasted
Saunier Duval F AS 30 EThemaclassicContrasted
Saunier Duval F 17 EOpaliaContrasted
Saunier Duval F 17 EOpaliafastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5744100 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5744100. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch S5744100 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The extractor works, but the boiler does not start and gets locked.

    Cause: The pressure switch does not detect the extractor's depression, which prevents the boiler from igniting.

    Check that the silicone tubes between the pressure switch and the fan are not pinched, bent, or disconnected.

  • 02

    The boiler does not ignite and the fan does not spin as it should.

    Cause: If the extractor does not reach the necessary speed, it does not create the depression that the pressure switch needs to operate, even if it is functioning properly.

    Check that the fan rotates freely by hand with the boiler unplugged, without any friction or resistance.

  • 03

    The problem occurs after cleaning or inspecting the boiler.

    Cause: When disassembling the flue or the extractor, it is possible that some pipe is not properly positioned, causing the same fault as a broken pressure switch.

    Check that all pipes and fittings are properly connected after any handling before considering the spare part.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
02Air flow safety.The air pressure switch S5744100 does not switch when the fan starts or does not detect the depression due to obstruction in tubes/venturi; check with a multimeter or manometer that the pressure switch changes state with the fan running and inspect tubes and connections.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Saunier Duval pressure switch S5744100

Catalogue reference
S5744100
Brand
Saunier Duval
Type of part
Pressure switches
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Set (opening/closing)
59/51 Pa
Contact electric charge
1(0.5) A / 250 V~
Component code
605.99534
Internal code
116189
Batch code
EJMADF
Manufacturing date
week 03 of 2005
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch S5744100

Does this pressure switch Ref. S5744100 work for my Saunier Duval Isofast F 35 E1?
Yes, the Isofast F 35 E1 is on the list of compatible boilers.
What are the opening and closing pressure settings for the pressure switch S5744100?
59/51 Pa (opening/closing), according to the original label of the part.
What code is engraved on the pressure switch of the Themafast F25E?
605.99534, in addition to the internal code 116189 and batch EJMADF.
What fault indicates that this pressure switch needs to be replaced in the Opalia F 17 E?
Detect the depression created by the extractor before allowing ignition; if it does not switch, the boiler will not start or will lock out.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model