Honeywell/Yamatake Pressure Switch C6065FH1706:2 - Cointra Supra Compact SPC 21 EI

Honeywell/Yamatake Pressure Switch C6065FH1706:2 - Cointra Supra Compact SPC 21 EI

Stock · 1 unit

Honeywell pressure switch, co-branded Yamatake, model C6065FH1706:2, set at 0.68 mbar with a maximum allowable of 6 mbar, powered at 250V~. It is installed in the Cointra Supra Compact SPC21EI and in various Baxi Roca and Roca boilers. It is replaced when the boiler does not properly detect the pressure and either locks out or fails to start.

VAT included

Compatibility

Cointra boilers compatible with reference 9158747

Pressure switch with reference 9158747. A proven compatibility: SPC 21 EI.

Proven compatibility

Boiler modelFamilyVerification
Cointra SPC 21 EISupra CompactContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 9158747 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 9158747. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 9158747 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start or locks out right after the fan starts spinning.

    Cause: The pressure switch does not detect the depression generated by the extractor, and the control unit interprets that there is not enough smoke evacuation.

    Check that the fan spins freely and without unusual noises, and that the flue is not blocked, before declaring the part defective.

  • 02

    The ignition fault is intermittent; today it starts fine, and tomorrow it locks out for no apparent reason.

    Cause: A contact that begins to degrade from use may close irregularly before failing permanently.

    Check the silicone pressure tubes: if they are dry, cracked, or poorly fitted, they exhibit the same symptoms as a faulty pressure switch.

  • 03

    The boiler locks out mainly during strong winds or on days with a lot of air around the chimney area.

    Cause: This pressure switch operates within a set pressure range, and an external airflow at the flue outlet can alter the reading and cause occasional blockages.

    Note if the fault occurs with wind or also happens under normal conditions, to rule out an external cause before replacing the part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Cointra pressure switch 9158747

Catalogue reference
9158747
Brand
Cointra
Type of part
Pressure switches
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component code
C6065FH1706:2
Start capacitor / voltage
1.5(0.5) µF · 250V~
Set pressure (P+)
P=0.68 mbar
Maximum allowable pressure
max. 6 mbar
CE code
CE-0063AP3085/1
Internal microswitch
V-561QR-041 · 1.5A-250VAC · V170
Frequently Asked Questions

Frequently asked questions about the pressure switch 9158747

Is the Honeywell/Yamatake C6065FH1706:2 pressure switch suitable for my Cointra Supra Compact SPC 21 EI?
Yes, it is compatible with the Cointra Supra Compact SPC 21 EI boiler.
What fault does this pressure switch solve in the Cointra Supra Compact boiler?
It is replaced when the boiler does not properly detect the pressure and locks out or fails to start.
At what pressure does the pressure switch C6065FH1706:2 operate?
It is set to 0.68 mbar, with an allowable maximum of 6 mbar.
How many models are compatible with the pressure switch C6065FH1706:2?
This pressure switch is compatible with a total of 1 model, which is the Cointra Supra Compact SPC 21 EI.
What is the reference for the pressure switch for the Cointra Supra Compact?
The reference of the pressure switch is PCS21EI.

Spare parts related to Cointra Supra Compact

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model