Saunier Duval Air Pressure Switch Isofast F30 E / Themafast F30 E - Ref. 605.99534
Differential air pressure switch for Saunier Duval boilers, with a switching setting of 59/51 Pa printed on the label and part code 605.99534. It controls the pressure generated by the fan before allowing the burner to ignite. It is replaced when the boiler does not start, locks during ignition, or shows an air pressure switch error.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5744100
Pressure switch with reference S5744100. 21 verified compatibilities: F 30 E H-MOD and F 35 E1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E1 | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 28 E2 | Isomax | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isotwin | Contrasted |
| Saunier Duval F 30 E | Isosplit | Contrasted |
| Saunier Duval F 35 E | Isosplit | Contrasted |
| Saunier Duval F 35 E H-MOD | Isosplit | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 25 E | Thema | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
| Saunier Duval F AS 25 E | Thema | Contrasted |
| Saunier Duval F 25 E | Themaplus | Contrasted |
| Saunier Duval F 30 E | Themaplus | Contrasted |
| Saunier Duval F AS 30 E | Themaclassic | Contrasted |
| Saunier Duval F 17 E | Opalia | Contrasted |
| Saunier Duval F 17 E | Opaliafast | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5744100 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5744100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch S5744100 resolves.
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite but quickly shuts off or the burner does not start.
Cause: The pressure switch does not close the air contact, which causes the control board to cut off the gas for safety, even though the fan is working.
Check that the extractor is rotating correctly and at a good speed. Ensure that the silicone tubes of the pressure switch are not disconnected, crushed, or contain condensate water.
- 02
The display shows a fault or blockage related to air or flue gas evacuation, and it needs to be reset to attempt to ignite again.
Cause: The PCB indicates that the pressure switch does not confirm the minimum depression required to allow ignition.
Check the flue duct for any obstructions, such as birds, ice, or a blocked condensate trap that may reduce the draft, before replacing the part.
- 03
The extractor works normally, but the boiler gets locked and does not allow the gas to pass.
Cause: The pressure switch validates the pressure generated by the fan; if it does not switch, the control board interprets that there is no safe exhaust and does not open the gas valve.
With the boiler off, gently blow through one of the silicone tubes and listen for the pressure switch to click; if it doesn't switch, the fault may be in the tube or the connection, not in the part.
- 04
The fault is intermittent: sometimes it starts up properly and other times it locks up for no apparent reason.
Cause: A loose diaphragm or a loose connection can cause the pressure switch to toggle right at the limit and fail only with wind or back pressure.
Check that the electrical connectors (Faston) are properly fitted and free of rust, and that the pipes are not bent at any point along the route.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 02 | Air flow safety. | The air pressure switch S5744100 does not switch when the fan starts or does not detect the depression due to obstruction in tubes/venturi; check with a multimeter or manometer that the pressure switch changes state with the fan running and inspect tubes and connections. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for Saunier Duval pressure switch S5744100
- Catalogue reference
- S5744100
- Brand
- Saunier Duval
- Type of part
- Pressure switches
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Label code
- 605.99534
- Set (opening/closing)
- 59/51 Pa
- Contact electric charge
- 1(0.5)A / 250V~
- Internal code
- 116189
- Batch code
- SFSEFF
- Manufacturing date (week/year)
- 45/05