If your boiler does not start or gets blocked despite the pressure being correct, a technical diagnosis must confirm if you need the air pressure switch for the Themafast F 30 E boiler - Ref. 605.99534. This component checks the air pressure and allows the boiler to operate. When it fails, it may display the fault code 02: Air flow safety. It is compatible with models such as Themafast F 30 E, F 25 E, among others. A technician must confirm through diagnosis if it needs to be replaced if you notice that the boiler is not responding properly.
- Type of part
- Pressure switches
- Status
- Refurbished
- Catalogue reference
- S5744100
- Warranty
- 1 year
Saunier Duval boilers compatible with reference S5744100
Pressure switch with reference S5744100. 21 verified compatibilities: F 30 E H-MOD and F 35 E1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E1 | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 28 E2 | Isomax | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isotwin | Contrasted |
| Saunier Duval F 30 E | Isosplit | Contrasted |
| Saunier Duval F 35 E | Isosplit | Contrasted |
| Saunier Duval F 35 E H-MOD | Isosplit | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 25 E | Thema | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
| Saunier Duval F AS 25 E | Thema | Contrasted |
| Saunier Duval F 25 E | Themaplus | Contrasted |
| Saunier Duval F 30 E | Themaplus | Contrasted |
| Saunier Duval F AS 30 E | Themaclassic | Contrasted |
| Saunier Duval F 17 E | Opalia | Contrasted |
| Saunier Duval F 17 E | Opaliafast | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5744100 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5744100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the pressure switch S5744100
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite, the fan starts, but it stops and gets locked without producing a flame.
Cause: The pressure switch does not detect the correct air pressure, and the control board interrupts the ignition cycle for safety.
Make sure that the silicone tubes do not have accumulated condensate water and are not bent before changing the pressure switch.
- 02
The extractor works normally, but the boiler does not progress beyond that phase and gets blocked.
Cause: If the pressure switch does not close the contact despite the fan running well, the PCB understands that there is not enough draft.
Check that the connections of the tubes to the pressure switch and the duct are properly fitted and have not come loose.
- 03
The fault appears intermittently: some days it starts up well and others it gets blocked.
Cause: A partial obstruction or a variable condensation point in the pipe can cause the pressure switch to switch just at the limit of its setting.
Check the flue duct and the exterior outlet for any dirt, nests, or ice that may reduce the draft.
- 04
The boiler displays a fault code related to the fan or flue gas evacuation.
Cause: It is the typical warning given by the control board when the pressure switch remains open longer than expected after the fan starts.
Before replacing it, clean the dust extractor and check that it spins freely without rubbing.
Fault codes Saunier Duval that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| 02 | Air flow safety. | The air pressure switch S5744100 does not switch when the fan starts or does not detect the depression due to obstruction in tubes/venturi; check with a multimeter or manometer that the pressure switch changes state with the fan running and inspect tubes and connections. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for Saunier Duval pressure switch S5744100
- Catalogue reference
- S5744100
- Uniclima internal SKU
- PCTF30E
- Brand
- Saunier Duval
- Type of part
- Pressure switches
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Component code
- 605.99534
- Switching pressure (open/close)
- 59/51 Pa
- Contact current/voltage
- 1(0.5)A / 250V~
- Internal code
- 116189
- Batch code
- DLKEJD
- Week/year marking (not explained on the label)
- 49/03