Air Pressure Switch Isofast F 30 E - Code 605.99534
Air pressure switch (also known as differential or flue pressure switch), a component that compares the pressure generated by the fan with a set value and allows or blocks the burner ignition based on the result. It is replaced when the boiler does not ignite, locks with the fan running, or shows a draft fault error. Factory setting: 59/51 Pa.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5744100
Pressure switch with reference S5744100. 21 verified compatibilities: F 30 E H-MOD and F 35 E1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 30 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 35 E1 | Isofast | Contrasted |
| Saunier Duval F 35 E H-MOD | Isofast | Contrasted |
| Saunier Duval F 28 E2 | Isomax | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval F 30 E H-MOD | Isotwin | Contrasted |
| Saunier Duval F 30 E | Isosplit | Contrasted |
| Saunier Duval F 35 E | Isosplit | Contrasted |
| Saunier Duval F 35 E H-MOD | Isosplit | Contrasted |
| Saunier Duval F 25 E | Themafast | Contrasted |
| Saunier Duval F 25 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval F 30 E H-MOD | Themafast | Contrasted |
| Saunier Duval F 25 E | Thema | Contrasted |
| Saunier Duval F 25 E STL | Thema | Contrasted |
| Saunier Duval F AS 25 E | Thema | Contrasted |
| Saunier Duval F 25 E | Themaplus | Contrasted |
| Saunier Duval F 30 E | Themaplus | Contrasted |
| Saunier Duval F AS 30 E | Themaclassic | Contrasted |
| Saunier Duval F 17 E | Opalia | Contrasted |
| Saunier Duval F 17 E | Opaliafast | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5744100 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5744100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch S5744100 resolves.
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler starts the fan, stops for a few seconds, and tries again several times before locking.
Cause: The control unit tries to ignite the boiler when it does not receive the signal from the pressure switch at first, until it locks out for safety.
Count how many times it retries before locking; if it is always the same number of attempts and the same point, it could be a constant pressure issue.
- 02
The fault appears just when the weather changes, for example with fog or high humidity.
Cause: Moisture can condense inside the pressure intake tube and give a false reading of the pressure switch.
Check for water or condensation inside the silicone tubes that connect the pressure switch before replacing it.
- 03
The electrode or flame sensor has been replaced and the fault remains exactly the same.
Cause: If the lockout occurs during the pre-purge phase, before the spark, the problem is not in the flame section but in the flue gas validation performed by the pressure switch.
Check at what exact moment in the cycle the boiler locks: if it is before the spark, focus on the air circuit and the pressure switch, not on the electrode.
- 04
Before blocking, the extractor can be heard running normally, without any strange noises.
Cause: If the extractor sounds fine but the pressure switch still does not switch, the fault points more to the pressure switch itself or its air intake circuit than to the fan.
First, rule out the fan by the sound, and if it sounds normal, check the cleanliness and securing of the pressure intake pipes before purchasing the pressure switch.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 02 | Air flow safety. | The air pressure switch S5744100 does not switch when the fan starts or does not detect the depression due to obstruction in tubes/venturi; check with a multimeter or manometer that the pressure switch changes state with the fan running and inspect tubes and connections. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for Saunier Duval pressure switch S5744100
- Catalogue reference
- S5744100
- Brand
- Saunier Duval
- Type of part
- Pressure switches
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component code
- 605.99534
- Set (opening/closing)
- 59/51 Pa
- Contact electric charge
- 1(0.5)A / 250V~
- Internal code
- 116189
- Manufacturing date (week/year)
- 07/04
- Batch code
- K02RHE (alternative reading: KOZAHE, ambiguous characters)