Pressure switch Ariston Genus 27 BFFI

Pressure switch Ariston Genus 27 BFFI

Stock · 5 units

The Ariston Genus 27 BFFI pressure switch controls the air or water pressure in the boiler, allowing it to operate properly. If this part fails, the boiler may not start or may lock out, even if the actual pressure is correct. Users may notice issues such as fault code 607, where the flue pressure switch is active before the fan starts, or fault code 608, which indicates that the flue pressure switch does not activate even though the fan is running. This pressure switch is compatible with models such as the Genus 23 MFFI, 27 MFFI, among others. It is recommended to replace it when these symptoms or fault codes are detected.

VAT included

Compatibility

Ariston boilers compatible with reference 571652-01

Pressure switch with reference 571652-01. Ten confirmed compatibilities: 20 MFFI CE (Edition 2) and 24 MFFI CE (Edition 2).

Proven compatibility

Boiler modelFamilyVerification
Ariston 20 MFFI CE (Edition 2)DAYContrasted
Ariston 24 MFFI CE (Edition 2)DAYContrasted
Ariston System 27 RFFIDAYContrasted
Ariston A23 MFFIEurocombiContrasted
Ariston A27 MFFIEurocombiContrasted
Ariston 23 MFFIGenusContrasted
Ariston 27 BFFIGenusContrasted
Ariston 27 MFFIGenusContrasted
Ariston 27 RFFIGenusContrasted
Ariston 30 MFFIGenusContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 571652-01 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 571652-01. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 571652-01 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler locks up just when turning it on, without attempting to start.

    Cause: The pressure switch does not make proper contact before the fan starts, so the boiler does not begin to operate.

    Make sure that the electrical connector of the pressure switch is properly plugged in and that there are no loose wires before considering replacing it.

  • 02

    It always fails at the same moment when turning it on.

    Cause: If the pressure switch does not reach the correct pressure, it always blocks the boiler in the same phase, right after the pre-purge.

    With the boiler turned off, gently blow through the pressure tube and check if you hear or feel the click of the pressure switch when it changes.

  • 03

    The fault occurs more often when the boiler is cold, especially in the morning.

    Cause: Cold air is denser and can seal a small leak in the pressure circuit, which does not happen when it is hot.

    Check the gaskets and the silicone tube for any cracks or air leaks before blaming the pressure switch.

  • 04

    The boiler works well for several days and then locks out for no apparent reason.

    Cause: Dirt or soot accumulated in the pressure switch duct can affect the pressure reading.

    Disassemble and visually check that the air duct to the pressure switch is clean and free of soot or dust.

Fault codes for Ariston that this part resolves.

CodeFaultDiagnosis and solution
607The flue pressure switch is active before the fan starts.The air pressure switch seems to be closed before the fan starts to operate. This may be due to the contacts being stuck or the tube being pressed or blocked. Check the continuity of the pressure switch and the pressure difference at the intake and flue connections with a differential manometer (it should be around ~0.47 mbar at maximum power) and inspect the tubes.
608The flue pressure switch does not activate even though the fan is running.Even though the fan is running, the pressure switch does not close. This may be because the diaphragm is damaged, the tubes are blocked, or there is a poor fit. The PCB blocks the ignition due to lack of approval. Check that the pressure switch closes electrically when starting and measure the pressure difference with a differential manometer. Inspect the pressure switch hoses.
6P1The air pressure switch takes time to activate.The pressure switch takes time to close after the fan starts. This may be due to dirt, jamming of the micro switch, leaks in the pipes, or insufficient pressure difference. Check the time it takes to close and the pressure difference during startup with a differential manometer and a multimeter.
6P2The air pressure switch opens during operation.While the boiler is in operation, the pressure switch opens because the pressure drops. This may be due to a partial obstruction in the intake or flue, a leak in the pipes, or a faulty pressure switch. Check the stability of the contact and the pressure difference under load; inspect and replace the pressure switch if it does not maintain its state.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Ariston Pressure Switch 571652-01

Catalogue reference
571652-01
Brand
Ariston
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

PCB code
605.99509
Pressure differential
40 Pa / ΔP+12Pa
Contact features
0.2(0.1)/30~
Batch code
YVWEEB
Long code (possible mold/serial code)
2399551018000
Frequently Asked Questions

Frequently asked questions about the pressure switch 571652-01

What PCB code should I check on the pressure switch of the Ariston Genus 27 BFFI?
The code 605.99509, on the red label.
What does the text "MTS" printed on the pressure switch of the Genus 27 BFFI mean?
It is a text printed on the label; there is no confirmation that it is the manufacturer.
Is this pressure switch suitable for the Ariston Genus 27 MFFI?
Yes, it is on the list of compatible boilers for this part.
At what pressure does the pressure switch 605.99509 of the Genus 27 BFFI switch?
With a differential of 40 Pa (ΔP+12 Pa).