Honeywell Flue Pressure Switch for Biasi Micon 24 E - Ref. BI1036102

Honeywell Flue Pressure Switch for Biasi Micon 24 E - Ref. BI1036102

Stock · 5 units

Differential flue pressure switch that controls the proper evacuation of combustion gases before allowing the burner to ignite. If it does not detect the correct pressure in the flue pipe, it locks the boiler for safety. It is replaced when the boiler does not start due to a draft failure or the pressure switch does not close the contact despite the extraction working.

VAT included

Compatibility

Biasi boilers compatible with reference BI1036102

Pressure switch with reference BI1036102. A verified compatibility: Micon 24 E.

Proven compatibility

Boiler modelFamilyVerification
Biasi Micon 24 EMiconContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. BI1036102 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference BI1036102. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch BI1036102 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, but the flue fan seems to be working well.

    Cause: The flue pressure switch measures the pressure before and after the burner; if it does not detect the correct difference, it prevents ignition even if the extractor is functioning.

    Check that the flue duct is not obstructed (blocked terminal, accumulated condensation) before considering that the pressure switch is faulty.

  • 02

    The blockage is intermittent: some days the boiler starts without issues and other days it stops when starting.

    Cause: A smoke pressure switch with a damaged diaphragm can change state irregularly in response to small variations in draft.

    Check that the pressure take-off pipes are not condensating or bent; this is common in the flue side take-offs.

  • 03

    The flue and extraction have been checked and are functioning correctly, but the boiler keeps locking out.

    Cause: If the duct and the extractor are in good condition, it is possible that the pressure switch does not close the contact even if there is sufficient pressure.

    Check with a multimeter that the contact closes with the extractor running before replacing the part.

  • 04

    The boiler has been experiencing sporadic lockouts that are resolved by resetting.

    Cause: This is the typical behavior of a pressure switch that is at the limit of its adjustment, which changes state in an unstable manner before failing completely.

    Keep a record of when the fault occurs (cold, wind, after a reset) to confirm the pattern before replacing the part.

Fault codes for Biasi that this part resolves.

CodeFaultDiagnosis and solution
E05Flue pressure switch anomalyA problem has been detected in the flue gas evacuation. This can be dangerous and requires immediate attention. If you see this code, the flue pressure switch may be failing and needs to be replaced.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for the Biasi BI1036102 pressure switch

Catalogue reference
BI1036102
Brand
Biasi
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Honeywell (Yamatake)
Model / code
C6065FH1227:2
Voltage
250V~
Condenser
1.5(0.5) μF
Set pressure
1.33 mbar
Maximum pressure
6 mbar
CE code
CE-0063AP3085/1
Place of manufacture
Made in China
Batch code
0228F
Frequently Asked Questions

Frequently asked questions about the pressure switch BI1036102

What fault does this pressure switch resolve in the Micon 24 E?
It is replaced when the boiler does not start due to a draft fault or the pressure switch does not close the contact despite the flue extraction working.
Is it an air pressure switch or a flue pressure switch?
It is for flue gases: it controls the pressure of the combustion gases, according to the label and the catalog, not the air pressure of the burner.

Spare parts related to Biasi Micon

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model