Air Pressure Switch Boiler Chaffoteaux Niagara Delta 30 FF - 605.99581

Air Pressure Switch Boiler Chaffoteaux Niagara Delta 30 FF - 605.99581

Stock · 4 units

Air pressure switch (differential pressure) for Chaffoteaux Niagara Delta 30 FF boilers. It compares the pressure in the combustion circuit and only allows the ignition signal to pass if the fan is extracting correctly. It is replaced when the boiler does not start, locks before ignition, or shows a ventilation fault. Component code 605.99581, opening/closing differential 70/50 Pa.

VAT included

Compatibility

Chaffoteaux boilers compatible with reference 61307665-01

Pressure switch with reference 61307665-01. A proven compatibility: Niagara Delta 30 FF.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux Niagara Delta 30 FFNiagara DeltaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 61307665-01 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 61307665-01. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 61307665-01 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler locks out before igniting and the flame does not appear.

    Cause: The pressure switch measures the pressure of the combustion circuit; if it does not detect the correct difference, the control board does not allow ignition.

    Check that both pressure take-off pipes are connected and free of condensed water.

  • 02

    The display shows a ventilation fault or lack of draft, even though the fan sounds normal.

    Cause: The pressure switch confirms to the control board that there is sufficient draft; if it does not work, the warning is displayed even if the extractor is operational.

    Check the exhaust terminal outside; a partial obstruction (ice, nest, dirt) may prevent reaching the necessary pressure.

  • 03

    The fan works, but the burner does not start.

    Cause: Without the confirmation from the pressure switch, the control board cuts the cycle before opening the gas valve, even though the fan generates pressure.

    With a multimeter, check if the pressure switch closes the contact with the fan running before replacing it.

  • 04

    The fault occurs especially on windy days or in low temperatures.

    Cause: A pressure switch near the end of its useful life may not reach the necessary differential if the extractor encounters more resistance.

    Check if the blockage occurs under those conditions before considering the part as faulty.

Fault codes Chaffoteaux that this part resolves

CodeFaultDiagnosis and solution
21Absence of extraction flow (FF).The air pressure switch does not switch even though the extractor is activated (remains at 0) due to lack of depression/obstruction in inlets or a faulty pressure switch; verify by applying depression and measuring NO/NC continuity of the pressure switch and checking tubes/fan.
22Flue extraction detection device fault (FF).Short circuit in the 3-wire air pressure switch (NO/NC closing simultaneously or harness short) detected by the electronics; verify by disconnecting the 3-wire connector and measuring that NO and NC are not closed simultaneously, as well as inspecting wiring and moisture.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Chaffoteaux pressure switch 61307665-01

Catalogue reference
61307665-01
Brand
Chaffoteaux
Type of part
Pressure switches
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component code
605.99581
Pressure differential (open/close)
70/50 Pa
Electrical characteristics of the contact
1(0.5) A / 250 V~
Batch code
ROZAJD
Part number (batch)
1306946
Batch date
03/03 (probably March 2003)
Frequently Asked Questions

Frequently asked questions about the pressure switch 61307665-01

Is this pressure switch with code 605.99581 suitable for the Chaffoteaux Niagara Delta 30 FF BP and also for the N FR?
Yes, the catalog associates it with the BP, N FR, NAT, and P FR variants of the Niagara Delta 30 FF, as well as the Niagara Delta 30 kW.
What pressure does the pressure switch of the Niagara Delta 30 FF open and close at?
The opening and closing differential is 70/50 Pa according to the label.
What fault indicates that the pressure switch needs to be replaced on the Niagara Delta 30 FF?
The boiler does not start, it locks out before ignition, or shows a ventilation fault due to not detecting the correct fan pressure.

Spare parts related to Chaffoteaux Niagara Delta

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Air Pressure Switch Boiler Chaffoteaux Niagara Delta 30 FF - 605.99581