Plate Heat Exchanger Boiler Niagara Delta 30 FF
The plate heat exchanger of the Niagara Delta 30 FF boiler transfers heat from the primary circuit to the domestic hot water instantly. When it fails, the water comes out lukewarm or shows fluctuating temperatures, in addition to reducing the flow of hot water. This heat exchanger is compatible with several ranges, including models from the Aludra, Calydra, Elexia, Genus, Maya, MC2, Mira, and Primaxia series, among others. It is recommended to replace it when these symptoms are noticed to restore proper hot water production.
VAT included
Consult via WhatsAppCompatible Chaffoteaux boilers
Plate heat exchanger. Nine verified compatibilities: DELTA and CALYDRA.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux DELTA | ALUDRA | Contrasted |
| Chaffoteaux CALYDRA | CALYDRA | Contrasted |
| Chaffoteaux COMFORT | ELEXIA | Contrasted |
| Chaffoteaux HE 35 PLUS | GENUS | Contrasted |
| Chaffoteaux 28 FFN | MAYA | Contrasted |
| Chaffoteaux MC2 | MC2 | Contrasted |
| Chaffoteaux MIRA | LOOK | Contrasted |
| Chaffoteaux DELTA 30 FF | NIAGARA | Contrasted |
| Chaffoteaux PRIMAXIA | PRIMAXIA | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the plate heat exchanger resolves
The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The hot water does not reach the temperature you set on the control.
Cause: Limescale obstructs the exchange between the primary circuit and the domestic hot water circuit.
Measure the actual temperature with a thermometer at the tap closest to the boiler before ruling out other causes.
- 02
When opening the tap, the water takes time to come out hot and then the temperature varies.
Cause: The flow through the plates is irregular due to uneven scaling.
Test in various taps in the house: if it only occurs in the farthest one, it may be an installation issue and not a problem with the heat exchanger.
- 03
Water is leaking in the area of the heat exchanger.
Cause: A joint or weld in the plate pack has lost its tightness.
Locate the exact point of the dripping with the boiler off and running, to confirm that it comes from there and not from a nearby hose.
- 04
The water from the radiators comes out cloudy or with dark residues after intensive use of hot water.
Cause: An internal microcrack allows water from one circuit to mix with the other.
Bleed a radiator after intense use of domestic hot water and check if dirty water comes out; it is important to confirm this before replacing the part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Chaffoteaux plate heat exchanger datasheet
- Brand
- Chaffoteaux
- Type of part
- Plate heat exchanger
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- voltage
- 230V