Zilmet Fagor CE 24E N Domestic Hot Water Plate Heat Exchanger (and Compatible Models)
The Zilmet Fagor CE 24E N plate heat exchanger is a component that allows for the instantaneous transfer of heat from the primary circuit to the domestic hot water. When it fails, the water comes out lukewarm or with fluctuating temperatures, and the flow rate of domestic hot water is reduced. This heat exchanger is compatible with several boilers from the Contract Mini CE range, such as CE 24 E and CE 30 E, as well as from the FE and FEB ranges, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms occur to ensure an adequate supply of hot water.
- Type of part
- Plate heat exchanger
- Status
- Refurbished
- Catalogue reference
- MU0886000
- Warranty
- 1 year
Fagor boilers compatible with reference MU0886000
Plate heat exchanger with reference MU0886000. 11 verified compatibilities: CE 24 E and CE 30 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor CE 24 E | Contract Mini CE | Contrasted |
| Fagor CE 30 E | Contract Mini CE | Contrasted |
| Fagor FE 18 E | FE | Contrasted |
| Fagor FE 23 | FE | Contrasted |
| Fagor FE 24 E | FE | Contrasted |
| Fagor FE 26 E | FE | Contrasted |
| Fagor FE 27 E | FE | Contrasted |
| Fagor FE 30 E | FE | Contrasted |
| Fagor FEB 23 E | FEB | Contrasted |
| Fagor FEB 24 AR | FEB | Contrasted |
| Fagor FEB 24 E | FEB | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number MU0886000 is the one for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MU0886000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the plate heat exchanger MU0886000
The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Little hot water is coming out or the water reaches the tap lukewarm.
Cause: The plates are full of scale and do not transfer heat properly.
Check the water hardness of the installation and verify if there is a water softener; if there isn't, limescale is the main suspect.
- 02
The boiler takes longer than usual to heat the domestic hot water.
Cause: The flow between the plates decreases when there are accumulated limescale deposits.
Measure the time it takes for hot water to come out and compare it with that of another similar boiler that does not have this problem, if possible.
- 03
The heat exchanger is leaking or visibly losing water.
Cause: A joint or a welded area of the plate pack has become leaky.
Also check the nearby inlet and outlet fittings before considering the heat exchanger as responsible for the leak.
- 04
A noise similar to crackling is heard when the hot water circulates.
Cause: Limescale deposits cause turbulence by forcing water to flow between the plates.
Check if the noise occurs when domestic hot water is being used and disappears when only the heating is operating.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Plate heat exchanger data sheet Fagor MU0886000
- Catalogue reference
- MU0886000
- Uniclima internal SKU
- IPCE24EN
- Brand
- Fagor
- Type of part
- Plate heat exchanger
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Manufacturer of the heat exchanger
- Zilmet
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Fagor CE 24 E Manual (PDF) Document © Fagor, provided as a technical reference.