Zilmet Plate Heat Exchanger Boiler Fagor CE 30 E1 B Ref. MU0886000
Refurbished Fagor Plate heat exchanger Zilmet

Zilmet Plate Heat Exchanger Boiler Fagor CE 30 E1 B Ref. MU0886000

The Zilmet plate heat exchanger for the Fagor CE 30 E1 B boiler is responsible for transferring heat from the primary circuit to the domestic hot water instantly. When this part fails, the water comes out lukewarm or with fluctuating temperature, and the flow rate of DHW is reduced. This heat exchanger is compatible with several boiler models, including the Contract Mini CE range and the FE range, among others. A technician must confirm through diagnosis whether it needs to be replaced when the mentioned symptoms are noticed, to maintain efficiency in the supply of hot water.

Catalogue reference
MU0886000
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Fagor boilers compatible with reference MU0886000

Plate heat exchanger with reference MU0886000. 11 verified compatibilities: CE 24 E and CE 30 E.

Proven compatibility

Boiler modelFamilyVerification
Fagor CE 24 EContract Mini CEContrasted
Fagor CE 30 EContract Mini CEContrasted
Fagor FE 18 EFEContrasted
Fagor FE 23FEContrasted
Fagor FE 24 EFEContrasted
Fagor FE 26 EFEContrasted
Fagor FE 27 EFEContrasted
Fagor FE 30 EFEContrasted
Fagor FEB 23 EFEBContrasted
Fagor FEB 24 ARFEBContrasted
Fagor FEB 24 EFEBContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number MU0886000 is the one for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MU0886000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the plate heat exchanger MU0886000

The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The domestic hot water comes out lukewarm, especially after a while of showering.

    Cause: Limescale builds up on the plates, which reduces heat transfer to the domestic hot water.

    Increase the domestic hot water temperature on the panel and check if it improves: if it doesn't change, the problem may be with the heat exchanger.

  • 02

    The boiler makes a knocking or vibrating noise when requesting hot water.

    Cause: The deposits in the heat exchanger narrow the water flow, causing turbulence and noise.

    Check if the noise also occurs during heating or only when requesting domestic hot water: if it is only during domestic hot water, the problem could be the heat exchanger.

  • 03

    The heating circuit is losing pressure and needs to be refilled frequently.

    Cause: An internal leak between the plates of the heat exchanger allows water to pass from one circuit to another without dripping outside.

    Discard the expansion vessel, the safety valve, and the automatic air vents, which are common causes of pressure loss.

  • 04

    The domestic hot water comes out irregularly, sometimes hot and other times cold, without you having touched anything.

    Cause: A partial blockage due to scale causes an unstable water flow in the heat exchanger.

    Check the cold water inlet filter of the boiler before replacing the heat exchanger: if it is dirty, it can cause similar symptoms.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Plate heat exchanger data sheet Fagor MU0886000

Catalogue reference
MU0886000
Uniclima internal SKU
IPCE30EN
Brand
Fagor
Type of part
Plate heat exchanger
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

manufacturer
Zilmet
factory code
MU0886000
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the plate heat exchanger MU0886000

Does this Zilmet heat exchanger Ref. MU0886000 fit a Fagor CE 30 E 1 N?
The current catalog associates it with that model, but the confirmed compatibility list does not exactly include 'CE 30 E 1 N'; it does include CE24E1N, CE30E1B, FE24E1B, FE24E1N, FE26E1B, FE27E1B, FE30E1B, FEB23E, and FEB24AR. It is advisable to verify the exact model of your boiler.
Who manufactures the heat exchanger Ref. MU0886000 of the Fagor CE30E1B?
Zilmet, according to the readable oval logo on the part's label; Fagor is the brand of the boiler, not of this component.
Is the code MU0886000 factory marked on the part?
Yes, it is read directly on the label of the heat exchanger.
What is the function of this heat exchanger in the Fagor FE30E1B boiler?
Transfer heat between the internal circuits of the boiler.
Is this heat exchanger MU0886000 an original part from Fagor?
No. The actual manufacturer of the component is Zilmet; Fagor is the brand of the boiler, not of this part.

Spare parts related to Fagor FE

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Zilmet Plate Heat Exchanger Boiler Fagor CE 30 E1 B Ref. MU0886000