Zilmet Plate Heat Exchanger for Fagor Boiler CE-30E - Ref. MU0886000
Refurbished Fagor Plate heat exchanger Zilmet

Zilmet Plate Heat Exchanger for Fagor Boiler CE-30E - Ref. MU0886000

Plate heat exchanger for domestic hot water (DHW) production, manufactured by Zilmet, installed in Fagor boilers from the CE, FE, and FEB series. It transfers heat from the primary circuit to the domestic water. Replacement requires first confirming the fault of the part through technical diagnosis, even when leaks occur, the performance of the DHW drops, or there are limescale deposits that reduce water flow.

Catalogue reference
MU0886000
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Fagor boilers compatible with reference MU0886000

Plate heat exchanger with reference MU0886000. 11 verified compatibilities: CE 24 E and CE 30 E.

Proven compatibility

Boiler modelFamilyVerification
Fagor CE 24 EContract Mini CEContrasted
Fagor CE 30 EContract Mini CEContrasted
Fagor FE 18 EFEContrasted
Fagor FE 23FEContrasted
Fagor FE 24 EFEContrasted
Fagor FE 26 EFEContrasted
Fagor FE 27 EFEContrasted
Fagor FE 30 EFEContrasted
Fagor FEB 23 EFEBContrasted
Fagor FEB 24 ARFEBContrasted
Fagor FEB 24 EFEBContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number MU0886000 is the one for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MU0886000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the plate heat exchanger MU0886000

The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    There is no domestic hot water, or it comes out with very low pressure.

    Cause: The domestic hot water heat exchanger does not allow water to pass due to blockages in the plates.

    Open the domestic hot water tap fully and compare the flow rate with that of the cold water from the same outlet.

  • 02

    The hot water comes out lukewarm, neither cold nor really hot.

    Cause: The plates of the heat exchanger have deposits that prevent complete heat transfer.

    Increase the domestic hot water setting and test with the tap slightly open: if it improves by reducing the flow rate, it is likely that the heat exchanger is scaled.

  • 03

    Water is appearing in the area where the heat exchanger is located.

    Cause: The plates or gaskets of the heat exchanger may be leaking due to wear.

    Dry the area, turn on the boiler, and check if the dripping comes from the heat exchanger.

  • 04

    The heating pressure is low without any visible leaks outside the boiler.

    Cause: An internal perforation in the heat exchanger can allow water to mix between the heating and domestic hot water circuits.

    Fill it up to the correct pressure and check if it drops again in a few hours without any visible water on the floor.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Plate heat exchanger data sheet Fagor MU0886000

Catalogue reference
MU0886000
Uniclima internal SKU
IPCMCE30E
Brand
Fagor
Type of part
Plate heat exchanger
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Zilmet
Code
MU0886000
Before purchasing
  • Fagor is the brand of the boiler where it is installed; the actual manufacturer of the part is Zilmet, not Fagor.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the plate heat exchanger MU0886000

Is this heat exchanger suitable for a Fagor FE-27E?
Yes, the FE-27E is on the list of compatible boilers, along with CE-24E, CE-30E, FE-18E, FE-24E, FE-26E, FE-30E, FEB-23E, and FEB-24AR.
How do I check that the heat exchanger of my Fagor CE-30E is this part and not another?
Check that it has the code MU0886000 and the Zilmet logo printed.
What fault does replacing this heat exchanger in the Fagor FE-24E resolve?
It should be checked when leaks occur, the performance of the domestic hot water drops, or there are limescale deposits that reduce water flow. Replacement requires a technical diagnosis.

Spare parts related to Fagor FE

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Zilmet Plate Heat Exchanger for Fagor Boiler CE-30E - Ref. MU0886000