Zilmet Plate Heat Exchanger for Baxi Roca Boiler CE-30E - Ref. MU0886000
Plate heat exchanger for the production of domestic hot water (DHW), manufactured by Zilmet, installed in Fagor boilers from the CE, FE, and FEB series. It transfers heat from the primary circuit to the domestic water. It is replaced when leaks occur, the performance of the DHW drops, or there are limescale deposits that reduce water flow.
VAT included
Consult via WhatsAppFagor boilers compatible with reference MU0886000
Plate heat exchanger with reference MU0886000. 11 verified compatibilities: CE 24 E and CE 30 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor CE 24 E | Contract Mini CE | Contrasted |
| Fagor CE 30 E | Contract Mini CE | Contrasted |
| Fagor FE 18 E | FE | Contrasted |
| Fagor FE 23 | FE | Contrasted |
| Fagor FE 24 E | FE | Contrasted |
| Fagor FE 26 E | FE | Contrasted |
| Fagor FE 27 E | FE | Contrasted |
| Fagor FE 30 E | FE | Contrasted |
| Fagor FEB 23 E | FEB | Contrasted |
| Fagor FEB 24 AR | FEB | Contrasted |
| Fagor FEB 24 E | FEB | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number MU0886000 is the one for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MU0886000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the plate heat exchanger MU0886000 resolves.
The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
There is no domestic hot water, or it comes out with very low pressure.
Cause: The domestic hot water heat exchanger does not allow water to pass due to blockages in the plates.
Open the domestic hot water tap fully and compare the flow rate with that of the cold water from the same outlet.
- 02
The hot water comes out lukewarm, neither cold nor really hot.
Cause: The plates of the heat exchanger have deposits that prevent complete heat transfer.
Increase the domestic hot water setting and test with the tap slightly open: if it improves by reducing the flow rate, it is likely that the heat exchanger is scaled.
- 03
Water is appearing in the area where the heat exchanger is located.
Cause: The plates or gaskets of the heat exchanger may be leaking due to wear.
Dry the area, turn on the boiler, and check if the dripping comes from the heat exchanger.
- 04
The heating pressure is low without any visible leaks outside the boiler.
Cause: An internal perforation in the heat exchanger can allow water to mix between the heating and domestic hot water circuits.
Fill it up to the correct pressure and check if it drops again in a few hours without any visible water on the floor.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Plate heat exchanger data sheet Fagor MU0886000
- Catalogue reference
- MU0886000
- Brand
- Fagor
- Type of part
- Plate heat exchanger
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Zilmet
- Code
- MU0886000
- Fagor is the brand of the boiler where it is installed; the actual manufacturer of the part is Zilmet, not Fagor.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Fagor CE 30 E Manual (PDF)Document © Fagor, provided as a technical reference.