Zilmet Plate Heat Exchanger Boiler Fagor FEB 23E N Zilmet
Refurbished Fagor Plate heat exchanger Zilmet

Zilmet Plate Heat Exchanger Boiler Fagor FEB 23E N Zilmet

The Zilmet plate heat exchanger of the Fagor FEB 23E N boiler transfers heat from the primary circuit to the domestic hot water instantly. When it malfunctions, the water comes out lukewarm or with fluctuating temperature, and the flow rate of DHW is reduced. This model is compatible with boilers from the Contract Mini CE and FE ranges, such as the CE 24 E, CE 30 E, FE 18 E, FE 23, FE 24 E, FE 26 E, FE 27 E, and FE 30 E, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms of unstable temperature and low flow are detected.

Catalogue reference
MU0886000
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Fagor boilers compatible with reference MU0886000

Plate heat exchanger with reference MU0886000. 11 verified compatibilities: CE 24 E and CE 30 E.

Proven compatibility

Boiler modelFamilyVerification
Fagor CE 24 EContract Mini CEContrasted
Fagor CE 30 EContract Mini CEContrasted
Fagor FE 18 EFEContrasted
Fagor FE 23FEContrasted
Fagor FE 24 EFEContrasted
Fagor FE 26 EFEContrasted
Fagor FE 27 EFEContrasted
Fagor FE 30 EFEContrasted
Fagor FEB 23 EFEBContrasted
Fagor FEB 24 ARFEBContrasted
Fagor FEB 24 EFEBContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number MU0886000 is the one for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MU0886000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the plate heat exchanger MU0886000

The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The domestic hot water comes out lukewarm or takes a long time to heat up.

    Cause: The plates accumulate scale inside and transmit less and less heat to the water flowing through the domestic hot water circuit.

    Before replacing it, try a chemical cleaning of the heat exchanger and check if the performance improves.

  • 02

    A whistling or bubbling sound is noticeable when hot water runs through the boiler.

    Cause: The narrowed passage between obstructed plates creates turbulence in the water and produces that noise.

    Check if the noise decreases with lower flow, with the tap slightly open, before replacing the part: it helps to distinguish between obstruction and network pressure.

  • 03

    Moisture or a small puddle appears under the boiler when using the domestic hot water.

    Cause: A crack between plates allows water to leak out of the heat exchanger body.

    Dry the area well, activate the domestic hot water, and locate if the dripping originates right at the block of PCBs and not at a nearby connection.

  • 04

    The pressure in the heating circuit rises when a hot water tap is opened.

    Cause: A damaged PCB connects the heating circuit with the domestic hot water circuit inside the heat exchanger.

    Note the pressure on the manometer before and just after opening the domestic hot water tap to confirm if there is mixing between circuits.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Plate heat exchanger data sheet Fagor MU0886000

Catalogue reference
MU0886000
Uniclima internal SKU
IPCF2001
Brand
Fagor
Type of part
Plate heat exchanger
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

manufacturer
Zilmet
manufacturing origin
Made in Italy
Frequently Asked Questions

Frequently asked questions about the plate heat exchanger MU0886000

Who manufactures the plate heat exchanger for the Fagor FEB 23E N?
Zilmet, according to the readable logo on the original part label, manufactured in Italy.
What is the function of this heat exchanger in the Fagor FEB 23E N?
Transfers heat between the internal circuits of the boiler.
How do I know if my Fagor FEB 23E N is equipped with this Zilmet heat exchanger?
Check that the installed component has the Zilmet logo on the label; if your boiler does not have it, this part is not yours.

Spare parts related to Fagor FE

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Zilmet Plate Heat Exchanger Boiler Fagor FEB 23E N Zilmet