Fagor Boiler Plate Heat Exchanger — Ref. MU0886000 (equiv. Morco MCB2160)

Fagor Boiler Plate Heat Exchanger — Ref. MU0886000 (equiv. Morco MCB2160)

The plate heat exchanger for the Fagor boiler, with reference MU0886000, is a component that transfers heat from the primary circuit to the domestic hot water instantly. When it fails, the water may come out lukewarm or with fluctuating temperatures, in addition to reducing the flow of hot water. This heat exchanger is compatible with models from the Contract Mini CE range, such as the CE 24 E and CE 30 E, as well as from the FE range, including the FE 18 E and FE 30 E, among others. A technician must confirm through diagnosis whether replacement is necessary when these symptoms of malfunction are detected.

Catalogue reference
MU0886000
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Fagor boilers compatible with reference MU0886000

Plate heat exchanger with reference MU0886000. 11 verified compatibilities: CE 24 E and CE 30 E.

Proven compatibility

Boiler modelFamilyVerification
Fagor CE 24 EContract Mini CEContrasted
Fagor CE 30 EContract Mini CEContrasted
Fagor FE 18 EFEContrasted
Fagor FE 23FEContrasted
Fagor FE 24 EFEContrasted
Fagor FE 26 EFEContrasted
Fagor FE 27 EFEContrasted
Fagor FE 30 EFEContrasted
Fagor FEB 23 EFEBContrasted
Fagor FEB 24 ARFEBContrasted
Fagor FEB 24 EFEBContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number MU0886000 is the one for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MU0886000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the plate heat exchanger MU0886000

The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The domestic hot water comes out with less force than before, even though the tap is fully open.

    Cause: The plates of the heat exchanger are getting clogged with limescale, narrowing the water flow.

    Compare the pressure of the hot water with that of the cold water at the same tap; if only the hot water loses pressure, suspect the heat exchanger.

  • 02

    There is moisture or dripping around the boiler that wasn't there before.

    Cause: Over the years, the joints between the plates lose tightness and the heat exchanger starts to leak water.

    Dry the area, demand domestic hot water and heating at the same time, and observe if the dripping reappears before declaring the part as lost.

  • 03

    The domestic hot water sometimes comes out with a color or smell that is not usual.

    Cause: A perforated plate allows water to pass between the heating circuit and the domestic hot water circuit.

    Compare the appearance and smell of the hot water from a tap far from the boiler before concluding that the heat exchanger is damaged.

  • 04

    The heating works normally, but the domestic hot water does not reach the set temperature.

    Cause: A plate heat exchanger with reduced effective surface area transfers less heat than it should.

    Check if the problem is more noticeable when several taps are open at the same time, which is the moment of highest demand, before replacing it.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Plate heat exchanger data sheet Fagor MU0886000

Catalogue reference
MU0886000
Uniclima internal SKU
IBCCE30E
Brand
Fagor
Type of part
Plate heat exchanger
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Number of PCBs
13, in stainless steel
Frequently Asked Questions

Frequently asked questions about the plate heat exchanger MU0886000

Does this heat exchanger MU0886000 work for a Morco boiler in the British market?
Yes, it corresponds to the reference Morco MCB2160, the same part marketed under another brand in that market.
When should the heat exchanger of the FEB24E be replaced?
It should be checked when it loses tightness or stops transferring heat effectively. Replacement requires a technical diagnosis.

Spare parts related to Fagor FE

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Fagor Boiler Plate Heat Exchanger — Ref. MU0886000 (equiv. Morco MCB2160)