SWEP Plate Heat Exchanger for Boiler Fagor FC 24/24-1 N - Ref. MUC080084
Refurbished Fagor Plate heat exchanger SWEP

SWEP Plate Heat Exchanger for Boiler Fagor FC 24/24-1 N - Ref. MUC080084

Plate heat exchanger manufactured by SWEP (model E6Tx14), with sales reference MUC080084. It is installed in Fagor boilers FC 24/24-1 N, FC 24/28-1 N, and FC2424N. It transfers heat between the primary circuit and the domestic hot water circuit. The replacement requires first confirming the fault of the part through technical diagnosis, even when there is a loss of tightness between plates, leaks appear, or the boiler stops heating the DHW regularly.

Catalogue reference
MUC080084
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Fagor boilers compatible with reference MUC080084

Plate heat exchanger with reference MUC080084. A proven compatibility: FC 24/24 N.

Proven compatibility

Boiler modelFamilyVerification
Fagor FC 24/24 NFagor FC (Natural)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part MUC080084 is the one for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MUC080084. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the plate heat exchanger MUC080084

The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The hot water comes out lukewarm or cuts off and comes back while you are showering.

    Cause: The heat exchangers lose exchange capacity due to scale, and the boiler does not maintain a stable temperature for domestic hot water.

    Check the flow rate and the inlet water pressure before considering that it is the heat exchanger; a low flow rate produces similar symptoms.

  • 02

    Water or a moisture ring appears between the plates of the heat exchanger.

    Cause: The package of plates can lose tightness due to a worn gasket or a damaged plate, and water leaks outside.

    Dry the area and check if the leak reappears as soon as you turn on the boiler to confirm that it is coming from there.

  • 03

    The heating pressure rises for no reason, and sometimes the domestic hot water takes on a strange appearance.

    Cause: If a PCB is perforated, the water from the primary circuit mixes with that of the domestic hot water circuit, altering the pressure and the appearance of the water.

    Check if the pressure in the heating circuit rises just when you open the hot water tap; if it does, it is a clear indication of mixing between circuits.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Plate heat exchanger data sheet Fagor MUC080084

Catalogue reference
MUC080084
Uniclima internal SKU
IPCFFC-24/24N
Brand
Fagor
Type of part
Plate heat exchanger
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
SWEP
Model SWEP
E6Tx14
Reference
MUC080084
Before purchasing
  • SWEP is the actual manufacturer of the part; Fagor is the brand of the boiler where it is installed, not the manufacturer of the heat exchanger.
Frequently Asked Questions

Frequently asked questions about the plate heat exchanger MUC080084

Who manufactures the heat exchanger for the Fagor FC 24/24-1 N?
It is manufactured by SWEP, although it is installed in Fagor boilers.
What model of SWEP is the heat exchanger MUC080084?
It is model E6Tx14, according to the printing on the PCB.
Does this heat exchanger fit the Fagor FC 24/28-1 N?
Yes, it is one of the three Fagor models with confirmed compatibility, along with FC 24/24-1 N and FC2424N.
What fault indicates that the heat exchanger needs to be replaced in the FC2424N?
It should be checked when it loses tightness between plates, leaks appear, or the boiler stops heating the domestic hot water regularly. Replacement requires a technical diagnosis.

Spare parts related to Fagor Fagor FC (Natural)

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
SWEP Plate Heat Exchanger for Boiler Fagor FC 24/24-1 N - Ref. MUC080084