Pressure switch Boiler Saunier Duval Thematek F 24 EBT - Ref. 605.99566
Pressure switch for Saunier Duval Thematek and Themaclassic boilers. It detects the pressure differential and allows or cuts off the ignition according to the set value: 48/35 Pa for opening and closing. Contact of 1(0.5)A at 250V. Replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler locks due to a pressure switch fault or does not correctly detect the working pressure.
- Type of part
- Pressure switches
- Status
- Refurbished
- Catalogue reference
- S1009800
- Warranty
- 1 year
Saunier Duval boilers compatible with reference S1009800
Pressure switch with reference S1009800. Two confirmed compatibilities: Thematek F 24 E and Thematek F 24 EBT.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Thematek F 24 E | Thematek | Contrasted |
| Saunier Duval Thematek F 24 EBT | Thematek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1009800 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1009800. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the pressure switch S1009800
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler ignites but turns off after a few seconds and shows a pressure switch fault.
Cause: The pressure switch stops working when the pressure drops, and the control board interprets that there is a safety issue.
Check that the pressure tube fitting is not leaking or loose: a small leak can cause the fault.
- 02
The lockouts appear and disappear on their own, without you having touched anything on the boiler.
Cause: A pressure switch with an old diaphragm loses accuracy and activates erratically depending on the ambient temperature.
Check if the fault occurs more frequently during the cold starts in the early hours than during the rest of the day.
- 03
The boiler doesn't even attempt to ignite: it remains dead with the fan stopped.
Cause: If the pressure switch remains open, the control board does not command the fan to start.
Before changing the pressure switch, confirm that the fan receives power and spins when the ignition command is given.
- 04
The condensate siphon has already been cleaned and the fault is still appearing the same.
Cause: The condensate siphon does not affect the air pressure switch, which depends on the extractor pressure and not on the condensate circuit.
First, rule out the condensate circuit and confirm that the fault persists with the siphon filled with water.
Fault codes Saunier Duval that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F 02 | Air fault / safety lack of draft (SRC or pressure switch). | The air pressure switch may not switch due to insufficient depression or may be faulty, causing the electronics to interpret a lack of draft; check the continuity of the pressure switch during start-up, the condition of the tubes, and the depression with a manometer while the fan is operating. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for the Saunier Duval pressure switch S1009800
- Catalogue reference
- S1009800
- Uniclima internal SKU
- PTF24EBT
- Brand
- Saunier Duval
- Type of part
- Pressure switches
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Model code
- 605.99566
- Opening/closing setting
- 48/35 Pa
- Contact
- 1(0.5)A / 250V~
- Batch
- YJHCHE
- Additional code
- 5220
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Thematek F 24 EBT Manual (PDF) Document © Saunier Duval, provided as a technical reference.