Honeywell Air Pressure Switch for Saunier Duval Isomax F 28 E2 - Ref. S57440
Air pressure switch Honeywell (factory code C6065FH1276:2) mounted on Saunier Duval boilers from the Isomax, Isofast, Opalia, and Themafast ranges. Check the depression generated by the extractor before allowing ignition. Opening setting at 0.53 mbar, maximum allowable pressure 6 mbar, contact of 1.5A at 250V~. The replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler does not validate the fan draft and locks out without igniting.
- Type of part
- Pressure switches
- Status
- Refurbished
- Catalogue reference
- S57440
- Warranty
- 1 year
Saunier Duval boilers compatible with reference S57440
Pressure switch with reference S57440. Ten verified compatibilities: Isofast F 28 E and Isofast F 28 E1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Isofast F 28 E | Isofast | Contrasted |
| Saunier Duval Isofast F 28 E1 | Isofast | Contrasted |
| Saunier Duval Isomax F 28 E | Isomax | Contrasted |
| Saunier Duval Isomax F 28 E2 | Isomax | Contrasted |
| Saunier Duval Isotwin F 24 E | Isotwin | Contrasted |
| Saunier Duval Opalia F 11 E | Opalia | Contrasted |
| Saunier Duval Opalia F 14 E | Opalia | Contrasted |
| Saunier Duval Opaliatherm TF 11 | Opaliatherm | Contrasted |
| Saunier Duval Opaliatherm TF 14 | Opaliatherm | Contrasted |
| Saunier Duval Themafast F 24 E | Themafast | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S57440 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S57440. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the pressure switch S57440
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The screen shows a fault code related to the pressure switch or air, not with the flame.
Cause: The control board identifies the type of fault based on which sensor is not validating; if the pressure switch does not close, the warning directly indicates that problem.
Note the exact code displayed by the boiler before purchasing anything; confirm if it indicates pressure switch/air or flame, and avoid replacing the wrong part.
- 02
The fault disappears for a moment if the pressure switch casing is gently tapped.
Cause: An internal contact with poor support can intermittently close due to vibration, even if the part is at the end of its useful life.
Do not leave it as a solution: if the fault changes when touching the part, it is a clear sign that the pressure switch is faulty, and not the rest of the installation.
- 03
The fault worsens when it is very windy or the boiler is in a very exposed area.
Cause: The wind at the exit terminal alters the depression generated by the extractor and may prevent the pressure switch from reaching its set point.
Check the location and condition of the flue terminal; if it is very exposed to the wind, rule out that cause first.
- 04
The extractor sounds different than it used to, more strained or weaker.
Cause: If the extractor does not create the usual depression, the pressure switch -even if it is functioning properly- never receives the signal it needs to switch.
Compare the sound and speed of the extractor with those before the fault; if they have changed, first check the extractor.
Fault codes Saunier Duval that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| 02 | Airflow fault. | The air pressure switch S57440 does not switch correctly (open when the fan starts or stuck/open circuit), so the PCB does not 'test' the draft; check continuity at its terminals during the ignition sequence, condition of the intake tubes (obstructions/leaks), and wiring/terminals. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Saunier Duval S57440 pressure switch datasheet
- Catalogue reference
- S57440
- Uniclima internal SKU
- PHIF28E2
- Brand
- Saunier Duval
- Type of part
- Pressure switches
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Manufacturer
- Honeywell (Yamatake-Honeywell)
- Factory code
- C6065FH1276:2
- Opening setting
- P= 0.53 mbar
- Maximum pressure
- Pmax. 6 mbar
- Contact
- 1.5(0.5)A / 250V~
- CE mark
- CE-0063AP3085/1
- Internal microswitch contact
- 1.5A-250VAC