Saunier Duval Semia Tek F 24 Air Pressure Switch Ref. 0020039198
Air pressure switch for Saunier Duval Semia Tek F24 boilers and for Protherm Gepard 23 MTV. It controls the differential pressure of the flue gas extraction circuit and allows ignition only if it detects correct draft. Factory set at 71/60 Pa (open/close), with a contact of 1(0.5) A at 250 V~. It is replaced when the boiler locks due to a pressure switch fault or does not detect extraction.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 0020039198
Pressure switch with reference 0020039198. Two confirmed compatibilities: Semia Tek F 24 and Semia Tek C 24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Semia Tek F 24 | Semia Tek | Contrasted |
| Saunier Duval Semia Tek C 24 | Semia Tek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 0020039198 is the part for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0020039198. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch 0020039198 resolves.
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite, you can hear the fan spinning, but it doesn't manage to light the flame and stops by itself.
Cause: The pressure switch does not detect the minimum air pressure, and the control board does not allow gas flow for safety reasons.
Check that the silicone tubes from the pressure switch to the fan are properly connected, without bends or accumulated water.
- 02
The display shows a flue or smoke evacuation fault warning and the boiler locks out.
Cause: It is the typical message when the pressure switch does not close the contact because there is not enough pressure in the duct.
Check the flue terminal outside: if it is blocked by a nest, ice, or dirt, the pressure switch will never give the ok even if it is functioning properly.
- 03
The extractor starts, stops, and restarts several times in a row without the boiler igniting.
Cause: It is the control board's attempt to achieve the switching pressure before permanently locking.
Check that the extractor spins freely and at a good speed, without any worn bearing noise, before confirming the fault of the pressure switch.
- 04
The boiler works well for a few seconds and then shuts off by itself, always at the same point in the ignition cycle.
Cause: The pressure switch loses contact because the pressure drops just when it should be maintained after startup.
With the boiler off, disconnect a small tube and gently blow into it to rule out that it is blocked by condensation or dust.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F02 | Air fault (SRC/VCM/flue pressure switch). | The air pressure switch does not switch when the fan starts due to a lack of pressure differential; check continuity in C–NO/C–NC and inspect the pressure switch tubes/venturi by applying vacuum/pressure. |
| 02 | Air fault (flow/draught safety). | The air pressure switch does not detect the required vacuum/overpressure and the boiler locks out; check with a manometer or test the micro switch closure by applying vacuum and inspect for obstructions in the pressure switch tubes. |
| F03 | Repetitive air fault (after several attempts). | If the air pressure switch does not open/close reliably during several starts, the boiler logs a repetition of F02; check the switching of the pressure switch and the tightness/cleanliness of the tubes and flue/venturi. |
| F33 | Air pressure switch open / air flow fault. | The pressure switch does not switch (or remains open) when the fan starts due to lack of draft or misaligned diaphragm; check the micro switch state change when generating differential and inspect the venturi/tubes and flue gas evacuation. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval pressure switch 0020039198
- Catalogue reference
- 0020039198
- Brand
- Saunier Duval
- Type of part
- Pressure switches
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure differential (open/close)
- 71/60 Pa
- Electric charge
- 1(0.5) A / 250 V~
- Part code
- 605.99755
- OEM reference
- 0020039198
- Date
- 05/10
- Batch (low confidence reading)
- 9ULC9FA