Manual Filling Valve for Boiler CONDENS F24E and Compatible Models – Ref. S1007000
It is the manual filling key of the boiler: it allows to refill the circuit with water and recover the operating pressure when it drops. The body is made of black plastic with a blue handle and a metal sleeve. It is operated manually and closes after filling. The replacement requires first confirming the fault of the part through technical diagnosis, even when it drips, does not close properly, or the handle gets stuck.
- Type of part
- Filling valves
- Status
- Refurbished
- Catalogue reference
- S1007000
- Warranty
- 1 year
Saunier Duval boilers compatible with reference S1007000
Filling key with reference S1007000. 23 verified compatibilities: C24E and C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C24E | ThemaClassic | Contrasted |
| Saunier Duval C25E | ThemaClassic | Contrasted |
| Saunier Duval F24E | ThemaClassic | Contrasted |
| Saunier Duval F25E | ThemaClassic | Contrasted |
| Saunier Duval C24E | Themafast | Contrasted |
| Saunier Duval C25E | Themafast | Contrasted |
| Saunier Duval C28E | Themafast | Contrasted |
| Saunier Duval F24E | Themafast | Contrasted |
| Saunier Duval F25E | Themafast | Contrasted |
| Saunier Duval F30E | Themafast | Contrasted |
| Saunier Duval C24E | Thematek | Contrasted |
| Saunier Duval F24E | Thematek | Contrasted |
| Saunier Duval F24E | Thema | Contrasted |
| Saunier Duval F25E | Thema | Contrasted |
| Saunier Duval THEMA24ECE | Thema | Contrasted |
| Saunier Duval THEMA24EFE | Thema | Contrasted |
| Saunier Duval C24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F25 Condens | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval Isofast F30E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isofast F35E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isomax F35 | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isotwin F30 | Isofast / Isomax / Isotwin Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1007000 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1007000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the filling valve S1007000
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Water leaks from the valve when opening or closing the handle.
Cause: The gasket between the control and the metal sleeve is worn and allows water to pass when the control is activated.
Close the control fully, dry the area, and check if the dripping comes from the metal socket or the plastic body before replacing it.
- 02
The boiler loses pressure and the circuit needs to be refilled frequently.
Cause: This valve is only used for refilling, so a constant loss of pressure is usually due to a leak in the circuit, not from the valve at rest.
Close it properly after refilling and check if the pressure drops again in the following days without touching anything.
- 03
The blue knob or the metal sleeve is broken or difficult to turn.
Cause: The metal sleeve protects the threading, but the control is made of plastic and can break if forced while being stuck.
If it is difficult to turn, try gently in both directions; if it is already broken, check if the socket allows you to operate the mechanism with a tool before replacing the entire part.
- 04
It doesn't close completely after refilling, and water keeps entering the circuit.
Cause: The internal seat does not seal properly, either due to wear or due to the accumulation of scale between the control and the body.
Turn the control to the fully closed position and check if the water flow stops completely before replacing the valve.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling key Saunier Duval S1007000
- Catalogue reference
- S1007000
- Uniclima internal SKU
- LLCI21F30B1
- Brand
- Saunier Duval
- Type of part
- Filling valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Body material
- Plastic, black color
- Control board
- Blue color
- Socket
- Metallic
- The body is made of black plastic with a blue handle and a metallic socket; if your key is of a different material or color, it is probably not this same part.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Thematek F24E Manual (PDF) Document © Saunier Duval, provided as a technical reference.