Filling Key Saunier Duval Isofast F 30 E H MOD Ref. S1007000
The Saunier Duval Isofast F 30 E H MOD Filling Key Ref. S1007000 is a tap that allows water to be replenished in the heating circuit, which is essential for maintaining the proper pressure in the system. If it malfunctions, the user will notice that they cannot refill the circuit or that it is continuously leaking water, which can lead to an increase in pressure. This part is compatible with boilers from the ThemaClassic, Themafast, Thematek, Thema, SemiaTek / Semia Condens, and Isofast / Isomax / Isotwin Condens ranges, among others. It is recommended to replace it when filling issues or water leaks are detected.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1007000
Filling key with reference S1007000. 23 verified compatibilities: C24E and C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C24E | ThemaClassic | Contrasted |
| Saunier Duval C25E | ThemaClassic | Contrasted |
| Saunier Duval F24E | ThemaClassic | Contrasted |
| Saunier Duval F25E | ThemaClassic | Contrasted |
| Saunier Duval C24E | Themafast | Contrasted |
| Saunier Duval C25E | Themafast | Contrasted |
| Saunier Duval C28E | Themafast | Contrasted |
| Saunier Duval F24E | Themafast | Contrasted |
| Saunier Duval F25E | Themafast | Contrasted |
| Saunier Duval F30E | Themafast | Contrasted |
| Saunier Duval C24E | Thematek | Contrasted |
| Saunier Duval F24E | Thematek | Contrasted |
| Saunier Duval F24E | Thema | Contrasted |
| Saunier Duval F25E | Thema | Contrasted |
| Saunier Duval THEMA24ECE | Thema | Contrasted |
| Saunier Duval THEMA24EFE | Thema | Contrasted |
| Saunier Duval C24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F25 Condens | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval Isofast F30E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isofast F35E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isomax F35 | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isotwin F30 | Isofast / Isomax / Isotwin Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1007000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1007000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve S1007000 resolves.
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
A drop of water comes out from the body of the tap or from the control when filling.
Cause: The seals of the valve wear out with use and allow water to pass when operated.
Dry the area well before opening the valve and check if the drop is coming from the body or from the connection thread to the circuit.
- 02
After filling to the correct pressure, it drops on its own again in a short time.
Cause: If the non-return valve does not seal, water can flow back into the network instead of remaining in the circuit.
Fill it, close the valve, and monitor the pressure gauge for the first 10-15 minutes; a rapid drop indicates that this part may be the issue.
- 03
Water is continuously dripping from the tap even when it is fully closed.
Cause: The closing seat is worn or has a trapped particle and does not close completely.
Tighten the knob a little more without forcing it and check if the dripping stops; if it doesn't stop, the wear is confirmed.
- 04
It is necessary to refill the pressure more frequently than normal without seeing any visible leaks.
Cause: A faulty closure in the valve allows water to leak into the network gradually even when it is closed.
Close the valve completely and monitor the pressure gauge without touching anything for a few hours; if it continues to drop, suspect this part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling key Saunier Duval S1007000
- Catalogue reference
- S1007000
- Brand
- Saunier Duval
- Type of part
- Filling valves
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Isofast F30E Manual (PDF)Document © Saunier Duval, provided as a technical reference.