Saunier Duval Isofast Angled Filling Valve Ref. S1007000

Saunier Duval Isofast Angled Filling Valve Ref. S1007000

Stock · 5 units

If you cannot refill water into the heating circuit or notice that water is continuously leaking, you may need the Saunier Duval Isofast Angle Filling Key Ref. S1007000. This key allows you to replenish the heating circuit to maintain the proper pressure. When it fails, you may experience pressure issues in the boiler. It is compatible with models from the ThemaClassic, Themafast, Thematek, Thema, SemiaTek, and Isofast ranges, among others. It should be replaced when it shows leaks or does not allow the circuit to be filled.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1007000

Filling key with reference S1007000. 23 verified compatibilities: C24E and C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C24EThemaClassicContrasted
Saunier Duval C25EThemaClassicContrasted
Saunier Duval F24EThemaClassicContrasted
Saunier Duval F25EThemaClassicContrasted
Saunier Duval C24EThemafastContrasted
Saunier Duval C25EThemafastContrasted
Saunier Duval C28EThemafastContrasted
Saunier Duval F24EThemafastContrasted
Saunier Duval F25EThemafastContrasted
Saunier Duval F30EThemafastContrasted
Saunier Duval C24EThematekContrasted
Saunier Duval F24EThematekContrasted
Saunier Duval F24EThemaContrasted
Saunier Duval F25EThemaContrasted
Saunier Duval THEMA24ECEThemaContrasted
Saunier Duval THEMA24EFEThemaContrasted
Saunier Duval C24SemiaTek / Semia CondensContrasted
Saunier Duval F24SemiaTek / Semia CondensContrasted
Saunier Duval F25 CondensSemiaTek / Semia CondensContrasted
Saunier Duval Isofast F30EIsofast / Isomax / Isotwin CondensContrasted
Saunier Duval Isofast F35EIsofast / Isomax / Isotwin CondensContrasted
Saunier Duval Isomax F35Isofast / Isomax / Isotwin CondensContrasted
Saunier Duval Isotwin F30Isofast / Isomax / Isotwin CondensContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1007000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1007000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the filling valve S1007000 resolves.

The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure needs to be refilled more frequently than usual, even though no leaks are visible in the boiler.

    Cause: An angled filling valve that does not seat properly can allow water to slowly pass into the system without visible dripping.

    Close the valve tightly and check with a dry cloth around the body for any moisture after a few hours.

  • 02

    The blue knob is difficult to turn, it's stiff or gets stuck halfway without fully opening or closing.

    Cause: Limescale and age can seize the internal mechanism of this type of angle valve, which is more sensitive to limescale buildup due to its design.

    Try gently turning the knob in both directions; if it doesn't give at all, avoid forcing it to prevent breaking the plastic body.

  • 03

    Water is leaking from the area where the plastic body joins the metal fitting.

    Cause: The joint between the plastic and brass is the weakest point of this model, and with thermal expansion, it may lose its seal.

    Gently tighten that joint if the assembly allows it and check if the leak stops before considering the entire piece broken.

  • 04

    After refilling, the pressure in the circuit does not increase even though it seems that some water is entering.

    Cause: The angle valve might be allowing water to pass at such a low rate that it doesn't compensate for what the circuit loses elsewhere.

    Check air vents, radiators, and other valves in the circuit in case the actual leak is elsewhere and not at this valve.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the filling key Saunier Duval S1007000

Catalogue reference
S1007000
Brand
Saunier Duval
Type of part
Filling valves
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the filling key S1007000

Is this angled filling valve suitable for the Saunier Duval Isofast?
Yes, Isofast is on the list of compatible boilers, along with Isomax, Isotwin, ThemaClassic, Thematek, and other models.
What material is the angled filling valve with a blue knob made of?
Black plastic body, with a metallic socket and blue knob.
When should the angled filling valve be replaced on the Thema24ECE?
When it drips, gets stuck, or the knob breaks and no longer closes properly.