Filling Key Saunier Duval Isotwin Condens F30 - Ref. S1007000

Filling Key Saunier Duval Isotwin Condens F30 - Ref. S1007000

Stock · 5 units

If you are unable to refill water into the heating circuit or notice that it is continuously leaking, you may need the filling key Saunier Duval Isotwin Condens F30 - Ref. S1007000. This part allows you to recover the system pressure, ensuring it operates correctly. It is installed in boilers from the ThemaClassic, Themafast, Thematek, Thema, SemiaTek / Semia Condens, and Isofast / Isomax / Isotwin Condens ranges, among others. It is advisable to replace it when you experience issues filling the circuit or observe a water leak.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1007000

Filling key with reference S1007000. 23 verified compatibilities: C24E and C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C24EThemaClassicContrasted
Saunier Duval C25EThemaClassicContrasted
Saunier Duval F24EThemaClassicContrasted
Saunier Duval F25EThemaClassicContrasted
Saunier Duval C24EThemafastContrasted
Saunier Duval C25EThemafastContrasted
Saunier Duval C28EThemafastContrasted
Saunier Duval F24EThemafastContrasted
Saunier Duval F25EThemafastContrasted
Saunier Duval F30EThemafastContrasted
Saunier Duval C24EThematekContrasted
Saunier Duval F24EThematekContrasted
Saunier Duval F24EThemaContrasted
Saunier Duval F25EThemaContrasted
Saunier Duval THEMA24ECEThemaContrasted
Saunier Duval THEMA24EFEThemaContrasted
Saunier Duval C24SemiaTek / Semia CondensContrasted
Saunier Duval F24SemiaTek / Semia CondensContrasted
Saunier Duval F25 CondensSemiaTek / Semia CondensContrasted
Saunier Duval Isofast F30EIsofast / Isomax / Isotwin CondensContrasted
Saunier Duval Isofast F35EIsofast / Isomax / Isotwin CondensContrasted
Saunier Duval Isomax F35Isofast / Isomax / Isotwin CondensContrasted
Saunier Duval Isotwin F30Isofast / Isomax / Isotwin CondensContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1007000 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1007000. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the filling valve S1007000 resolves.

The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shows low pressure or a water shortage error even though you have just refilled it.

    Cause: An internal leak in the valve, due to wear of its gasket, allows water to escape slowly without being visible from the outside.

    Check the pressure gauge after a few hours without manipulating the boiler; if it drops on its own and there are no visible leaks in other areas, suspect this part.

  • 02

    You notice humidity or dripping right in the area where the valve is installed.

    Cause: The internal seal of the valve loses tightness with use, and water finds its way out through there.

    Dry the area with a cloth and check a few minutes later if the dripping reappears exactly at that point before replacing the part.

  • 03

    The key gets stuck or doesn't turn when trying to open it to refill.

    Cause: The internal plastic mechanism gets clogged with limescale when it hasn't been used for a while.

    Try a gentle movement without forcing it; forcing the turn may break the body before confirming if the problem is just dirt.

  • 04

    You fill the circuit but the pressure doesn't rise at all.

    Cause: If the internal passage is blocked or the gasket does not open properly, the mains water does not enter the circuit.

    Confirm that the network valve is open and that the filling connection is not blocked or bent.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the filling key Saunier Duval S1007000

Catalogue reference
S1007000
Brand
Saunier Duval
Type of part
Filling valves
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Frequently Asked Questions

Frequently asked questions about the filling key S1007000

Is this filling valve with reference S1007000 suitable for an Isotwin Condens F30?
Yes. Its compatibility is confirmed with Isotwin Condens F30, as well as SemiaTek F24, Thema24ECE, Thema Condens F25, ThemaFast Condens F25, and ThemaClassic F25E.
What material is this filling valve for the ThemaFast Condens F25 made of?
It is a black plastic piece with a blue sleeve, the same type as other filling keys from this batch.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Filling Key Saunier Duval Isotwin Condens F30 - Ref. S1007000