Manual Filling Valve Isomax Condens F35E - Ref. S1007000
The manual filling valve allows you to replenish water in the heating circuit to recover pressure. If it fails, you will not be able to refill the circuit or it may continuously leak water, causing an increase in pressure. This component, from the brand Saunier Duval and reference S1007000, is compatible with boilers from the ThemaClassic, Themafast, Thematek, Thema, SemiaTek, and Isofast ranges, among others. It is recommended to replace it when you notice leaks or issues maintaining the proper pressure in the system.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1007000
Filling key with reference S1007000. 23 verified compatibilities: C24E and C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C24E | ThemaClassic | Contrasted |
| Saunier Duval C25E | ThemaClassic | Contrasted |
| Saunier Duval F24E | ThemaClassic | Contrasted |
| Saunier Duval F25E | ThemaClassic | Contrasted |
| Saunier Duval C24E | Themafast | Contrasted |
| Saunier Duval C25E | Themafast | Contrasted |
| Saunier Duval C28E | Themafast | Contrasted |
| Saunier Duval F24E | Themafast | Contrasted |
| Saunier Duval F25E | Themafast | Contrasted |
| Saunier Duval F30E | Themafast | Contrasted |
| Saunier Duval C24E | Thematek | Contrasted |
| Saunier Duval F24E | Thematek | Contrasted |
| Saunier Duval F24E | Thema | Contrasted |
| Saunier Duval F25E | Thema | Contrasted |
| Saunier Duval THEMA24ECE | Thema | Contrasted |
| Saunier Duval THEMA24EFE | Thema | Contrasted |
| Saunier Duval C24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F25 Condens | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval Isofast F30E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isofast F35E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isomax F35 | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isotwin F30 | Isofast / Isomax / Isotwin Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1007000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1007000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve S1007000 resolves.
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure gradually decreases, and the circuit needs to be manually refilled from time to time.
Cause: The manual valve allows the entry of mains water to recover pressure. If it does not close properly, pressure is lost over time.
Check for any visible leaks in radiators or bleed valves, as pressure loss without visible water is usually due to that.
- 02
It doesn't close completely and continues to drip water after use.
Cause: The blue cap and the body of the valve are responsible for closing the water flow. If the internal seat is worn, it does not seal properly.
Turn the blue cap until you feel a firm stop and wait a few minutes before considering that the key is faulty.
- 03
The blue cap or the body of the valve is broken and cannot be operated.
Cause: It is a part that is used occasionally. If it hasn't been moved for years, the plastic of the cap can become brittle and break when forced.
Do not force with tools if you feel hard resistance. First, try with your hand and apply a few drops of degreaser on the thread.
- 04
It is not known if the valve is open or closed.
Cause: The metal collar and the blue cap are the only visual references for the position in this model.
Mark the current position before manipulating it to avoid accidentally emptying the circuit by thinking it is closed.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.