Manual Filling Valve Saunier Duval Isofast C 28 E - Ref. S1007000
The manual filling valve allows you to replenish water to the heating circuit to recover pressure. If it fails, you will notice that you cannot refill the circuit or that it is continuously leaking water, which causes an increase in pressure. This component is compatible with several boilers, including the models C24E, C25E, C28E, F24E, F25E, and F30E from the ThemaClassic, Themafast, Thematek, Thema, SemiaTek, and Isofast ranges. It is recommended to replace it when you observe pressure issues or water leaks.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1007000
Filling key with reference S1007000. 23 verified compatibilities: C24E and C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C24E | ThemaClassic | Contrasted |
| Saunier Duval C25E | ThemaClassic | Contrasted |
| Saunier Duval F24E | ThemaClassic | Contrasted |
| Saunier Duval F25E | ThemaClassic | Contrasted |
| Saunier Duval C24E | Themafast | Contrasted |
| Saunier Duval C25E | Themafast | Contrasted |
| Saunier Duval C28E | Themafast | Contrasted |
| Saunier Duval F24E | Themafast | Contrasted |
| Saunier Duval F25E | Themafast | Contrasted |
| Saunier Duval F30E | Themafast | Contrasted |
| Saunier Duval C24E | Thematek | Contrasted |
| Saunier Duval F24E | Thematek | Contrasted |
| Saunier Duval F24E | Thema | Contrasted |
| Saunier Duval F25E | Thema | Contrasted |
| Saunier Duval THEMA24ECE | Thema | Contrasted |
| Saunier Duval THEMA24EFE | Thema | Contrasted |
| Saunier Duval C24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F25 Condens | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval Isofast F30E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isofast F35E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isomax F35 | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isotwin F30 | Isofast / Isomax / Isotwin Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1007000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1007000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve S1007000 resolves.
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
When opening the valve to fill the circuit, the pressure does not rise on the pressure gauge.
Cause: The internal mechanism is stuck or the passage seal is not closing properly, and the water is not entering the circuit.
Before declaring the valve faulty, check that the mains valve is open and that there is no trapped air in the circuit.
- 02
The faucet continuously drips water even when it's closed.
Cause: The seat or internal sealing gasket has worn out and no longer seals when closed.
Dry the area and observe for a few minutes with the boiler at rest; if the dripping comes from the body of the valve itself and not from a nearby connection, it is the part.
- 03
It's very hard to turn the key, or it has become completely stuck.
Cause: Lime and accumulated sediments seize up the internal plastic mechanism over time.
Try a gentle back-and-forth movement without forcing it before considering it stuck; sometimes it can be released by applying some moderate heat to the area.
- 04
The pressure keeps rising on its own after closing the valve.
Cause: The seal does not completely close, and water continues to slowly enter the circuit.
Close the valve completely and check the manometer 10-15 minutes later; if the pressure continues to rise, the fault is in the closure.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling key Saunier Duval S1007000
- Catalogue reference
- S1007000
- Brand
- Saunier Duval
- Type of part
- Filling valves
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Isofast F30E Manual (PDF)Document © Saunier Duval, provided as a technical reference.