Manual Filling Key Saunier Duval Themafast Condens F 30 Ref. S1007000
The manual filling key Saunier Duval Themafast Condens F 30, with reference S1007000, is a tap that allows you to refill water into the heating circuit to maintain the proper pressure. If this part fails, you will notice that you cannot refill the circuit or that it continuously leaks water, which causes an increase in pressure. It is installed in boilers from the ThemaClassic, Themafast, Thematek ranges, among others. It is advisable to replace it when it shows leaks or does not function properly.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S1007000
Filling key with reference S1007000. 23 verified compatibilities: C24E and C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C24E | ThemaClassic | Contrasted |
| Saunier Duval C25E | ThemaClassic | Contrasted |
| Saunier Duval F24E | ThemaClassic | Contrasted |
| Saunier Duval F25E | ThemaClassic | Contrasted |
| Saunier Duval C24E | Themafast | Contrasted |
| Saunier Duval C25E | Themafast | Contrasted |
| Saunier Duval C28E | Themafast | Contrasted |
| Saunier Duval F24E | Themafast | Contrasted |
| Saunier Duval F25E | Themafast | Contrasted |
| Saunier Duval F30E | Themafast | Contrasted |
| Saunier Duval C24E | Thematek | Contrasted |
| Saunier Duval F24E | Thematek | Contrasted |
| Saunier Duval F24E | Thema | Contrasted |
| Saunier Duval F25E | Thema | Contrasted |
| Saunier Duval THEMA24ECE | Thema | Contrasted |
| Saunier Duval THEMA24EFE | Thema | Contrasted |
| Saunier Duval C24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F24 | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval F25 Condens | SemiaTek / Semia Condens | Contrasted |
| Saunier Duval Isofast F30E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isofast F35E | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isomax F35 | Isofast / Isomax / Isotwin Condens | Contrasted |
| Saunier Duval Isotwin F30 | Isofast / Isomax / Isotwin Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1007000 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1007000. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve S1007000 resolves.
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler pressure drops more frequently than normal, without any visible leaks.
Cause: The closing seat of the valve is worn and allows water to pass slowly even when it is closed.
Close the valve completely and observe the manometer for a couple of hours; if the pressure continues to drop, this part may be the cause.
- 02
Moisture, a ring of lime, or even a fine crack appears around the faucet.
Cause: The plastic of the valve becomes brittle due to heat and may crack in the threaded area.
With the boiler cold, visually inspect the body and the thread for cracks or remnants of dry scale before requesting the spare part.
- 03
The key switch is difficult to turn or is stuck.
Cause: The accumulation of limescale can clog the mechanism if the tap has not been used for a while.
Try to move the control gently; if it doesn't move, do not force the plastic as you could break it.
- 04
After filling, the pressure does not hold and drops quickly within a few minutes.
Cause: If the internal non-return valve of the tap is not functioning properly, water may flow back into the network.
Fill up to the recommended pressure, close the valve, and monitor the manometer during the first few minutes to see if the pressure drops quickly.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling key Saunier Duval S1007000
- Catalogue reference
- S1007000
- Brand
- Saunier Duval
- Type of part
- Filling valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Themafast C28E Manual (PDF)Document © Saunier Duval, provided as a technical reference.