Filling Key for Saunier Duval Thema/Isofast Boiler - Ref. SDS10068
If you notice that you cannot fill the heating circuit or that the pressure continuously rises due to a leak, you may need the filling key for the Saunier Duval Thema/Isofast boiler. This part allows you to replenish water to the heating circuit to maintain the proper pressure. It is installed in boilers from the Themaclassic, Themafast, Thematek, and Thema ranges, among others. It is advisable to replace it when it shows faults, such as water leaks or difficulties in filling.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference SDS10068
Filling key with reference SDS10068. 20 verified compatibilities: Themaclassic F24 and Themaclassic F25.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Themaclassic F24 | Themaclassic | Contrasted |
| Saunier Duval Themaclassic F25 | Themaclassic | Contrasted |
| Saunier Duval Themaclassic C24E | Themaclassic | Contrasted |
| Saunier Duval Themaclassic C25E | Themaclassic | Contrasted |
| Saunier Duval Themaclassic F 24 E | Themaclassic | Contrasted |
| Saunier Duval Themafast C24E | Themafast | Contrasted |
| Saunier Duval Themafast C25E | Themafast | Contrasted |
| Saunier Duval Themafast C28E | Themafast | Contrasted |
| Saunier Duval Themafast F24E | Themafast | Contrasted |
| Saunier Duval Themafast F25E | Themafast | Contrasted |
| Saunier Duval Themafast F30 | Themafast | Contrasted |
| Saunier Duval Themafast F30E | Themafast | Contrasted |
| Saunier Duval Thematek F24E | Thematek | Contrasted |
| Saunier Duval Thematek C24E | Thematek | Contrasted |
| Saunier Duval Thematek C24 EO | Thematek | Contrasted |
| Saunier Duval Thematek SC24E | Thematek | Contrasted |
| Saunier Duval Thematek SF24E | Thematek | Contrasted |
| Saunier Duval Thema F24E | Thema | Contrasted |
| Saunier Duval Thema F25 | Thema | Contrasted |
| Saunier Duval Thema NOx F25 B | Thema | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. SDS10068 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference SDS10068. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve SDS10068 resolves.
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure in the heating circuit is gradually rising without anyone having touched anything.
Cause: If the internal seat of the valve does not close completely, it allows a continuous drip of mains water into the circuit.
Close the valve completely and check the gauge needle; if it continues to rise after a couple of hours, the valve is not sealing properly.
- 02
Humidity or a droplet of water appears in the area of the valve, even when it is closed.
Cause: The gasket or the shaft of the valve wears out over the years, and the mains water eventually leaks outside the body.
Dry the area well and check a few hours later if the moisture reappears with the valve closed; if it only gets wet when you open it, the hose may be the issue.
- 03
It is very difficult to turn the key to refill, or it gets stuck halfway.
Cause: The limescale from the mains water accumulates in the internal mechanism and clogs it, especially in taps that are used infrequently.
Try gentle back-and-forth movements before forcing it; many times it releases and does not need to be replaced.
- 04
When opening to fill the circuit, very little water enters or it takes a long time to regain pressure.
Cause: If the internal passage of the valve is partially obstructed by limescale or debris, the flow it allows is insufficient.
Check that the main water shut-off valve is fully open; it is the most common cause of this symptom.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.