Filling Key for Saunier Duval Thema/Isofast Boiler - Ref. SDS10068

Filling Key for Saunier Duval Thema/Isofast Boiler - Ref. SDS10068

Stock · 4 units

If you notice that you cannot fill the heating circuit or that the pressure continuously rises due to a leak, you may need the filling key for the Saunier Duval Thema/Isofast boiler. This part allows you to replenish water to the heating circuit to maintain the proper pressure. It is installed in boilers from the Themaclassic, Themafast, Thematek, and Thema ranges, among others. It is advisable to replace it when it shows faults, such as water leaks or difficulties in filling.

VAT included

Compatibility

Saunier Duval boilers compatible with reference SDS10068

Filling key with reference SDS10068. 20 verified compatibilities: Themaclassic F24 and Themaclassic F25.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Themaclassic F24ThemaclassicContrasted
Saunier Duval Themaclassic F25ThemaclassicContrasted
Saunier Duval Themaclassic C24EThemaclassicContrasted
Saunier Duval Themaclassic C25EThemaclassicContrasted
Saunier Duval Themaclassic F 24 EThemaclassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast F24EThemafastContrasted
Saunier Duval Themafast F25EThemafastContrasted
Saunier Duval Themafast F30ThemafastContrasted
Saunier Duval Themafast F30EThemafastContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek C24 EOThematekContrasted
Saunier Duval Thematek SC24EThematekContrasted
Saunier Duval Thematek SF24EThematekContrasted
Saunier Duval Thema F24EThemaContrasted
Saunier Duval Thema F25ThemaContrasted
Saunier Duval Thema NOx F25 BThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. SDS10068 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference SDS10068. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the filling valve SDS10068 resolves.

The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure in the heating circuit is gradually rising without anyone having touched anything.

    Cause: If the internal seat of the valve does not close completely, it allows a continuous drip of mains water into the circuit.

    Close the valve completely and check the gauge needle; if it continues to rise after a couple of hours, the valve is not sealing properly.

  • 02

    Humidity or a droplet of water appears in the area of the valve, even when it is closed.

    Cause: The gasket or the shaft of the valve wears out over the years, and the mains water eventually leaks outside the body.

    Dry the area well and check a few hours later if the moisture reappears with the valve closed; if it only gets wet when you open it, the hose may be the issue.

  • 03

    It is very difficult to turn the key to refill, or it gets stuck halfway.

    Cause: The limescale from the mains water accumulates in the internal mechanism and clogs it, especially in taps that are used infrequently.

    Try gentle back-and-forth movements before forcing it; many times it releases and does not need to be replaced.

  • 04

    When opening to fill the circuit, very little water enters or it takes a long time to regain pressure.

    Cause: If the internal passage of the valve is partially obstructed by limescale or debris, the flow it allows is insufficient.

    Check that the main water shut-off valve is fully open; it is the most common cause of this symptom.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the filling key Saunier Duval SDS10068

Catalogue reference
SDS10068
Brand
Saunier Duval
Type of part
Filling valves
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Frequently Asked Questions

Frequently asked questions about the filling valve SDS10068

Is this filling key suitable for the Saunier Duval Semia Condens 25 boiler?
Yes, the Semia Condens25 is listed among the compatible models in this document.
Is the reference SDS10068 for this filling key a confirmed data?
No, it is the reference published today by the store, not a data confirmed by marking or external sources; it is advisable to verify it against your part.
Is this filling key suitable for the Isotwin F 30A boiler?
Yes, the Isotwin F 30A appears in the list of compatible boilers in this document.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Filling Key for Saunier Duval Thema/Isofast Boiler - Ref. SDS10068