Chaffoteaux Circulating Pump MC 2 24 FF Grundfos Ref. 61301964
RefurbishedChaffoteauxPumps

Chaffoteaux Circulating Pump MC 2 24 FF Grundfos Ref. 61301964

100 €VAT includedIn stock · 5 units

Circulating pump: refurbished spare part that circulates water in the heating circuit. Useful if there is noise, water is not circulating, or radiators do not heat evenly. Compatible with MX2, MX2 24 FF, Compy MX2 24 FF (ref. 61301964). Includes a one-year warranty and delivery within 2–4 working days in the EU.

1
Consult via WhatsApp
Delivery in 2–4 working days
1-year warranty
14-day return
Technical support

Key Data

Reference
61301964
Brand
Chaffoteaux
Type of part
Pumps
Available units
5 units in stock
Status
Refurbished
Warranty
1 year
Shipping
2–4 working days (EU)
Return
14 days

The same part (ref. 61301964) equips these models. Verified compatibility; check the reference before purchasing.

MX2

  • MX2
  • MX2 24 FF
  • Compy MX2 24 FF

B60

  • B60 30 BFFI

Fault codes related to this part (not the entire boiler). They usually have more possible causes: first rule out electrodes, wiring/connections, and gas supply. Verified with ≥3 sources.

CodeWhat does it mean?Cause and diagnosis (this part)
60-70-80Lack of water circulationThe circulating pump (stuck, seized, with air or without power) prevents the primary flow and triggers this code; check 230 V at the pump, bleed the circuit, and release/confirm shaft rotation from the front cap.
How do I know if this pump is for my boiler?
Verify reference 61301964 and ensure your model is on the list of compatible ones; compare connections and measurements. Install a Grundfos IT TF 95 pump.
Which models is it suitable for?
Pump shared by various models (see Compatibility). If your model does not appear, send us a photo and we will confirm it.
My boiler is making noise or the water isn't circulating, is it the pump?
Typical pump symptoms: noise or humming, rotor seized after a long stop, radiators not heating evenly, or shutdowns due to overheating. Check that the rotor turns and that the circuit bleeds properly.
Do you need to bleed it after changing it?
Yes. After installation, bleed the air from the circuit and the pump itself, and check the pressure at 1–1.5 bar with the boiler cold.
What pump does it exactly have?
Install a Grundfos IT TF 95 pump. Compare the body, connections, and electrical connector with the original before installing.
What does refurbished mean and what coverage does it have?
Part removed from a boiler out of service, inspected and tested. Includes 1-year warranty and 14-day return policy. Delivery within 2–4 working days in the EU.