Grundfos Circulating Pump VPAL-5/2M For Vaillant VM/VMW Ref. 178983
RefurbishedVaillantPumpsGrundfos

Grundfos Circulating Pump VPAL-5/2M For Vaillant VM/VMW Ref. 178983

Stock · 1 unit

Grundfos VPAL-5/2M circulating pump, sold under the Vaillant brand (P/N Grundfos 59866552, ref. Vaillant 178983), for Vaillant VM and VMW boilers from series 226 to 346 (3-3 to 5-3). It circulates the heating circuit water at two speeds (75 W / 85 W). It is replaced when the boiler does not heat despite turning on, makes pump noise, or the pump does not rotate.

VAT included

Compatibility

Vaillant boilers compatible with reference 178983

Circulating pump with reference 178983. 16 verified compatibilities: VMW ES 296/3-5 and VMW 296/3-5.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW ES 296/3-5ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 296/3-5ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 296/3-5 R3ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 296/3-5 R5ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 226/3-3ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 236/3-5ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 24/280/3-5ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 24/282/4-5 RVecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 280/3-5ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 286/5-3ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VMW 346/3-5ecoTEC plus / pro (VMW combi)Contrasted
Vaillant VM 240/3-5ecoTEC plus / pro (VM heating only)Contrasted
Vaillant VM 242/4-5ecoTEC plus / pro (VM heating only)Contrasted
Vaillant VM 246/3-5ecoTEC plus / pro (VM heating only)Contrasted
Vaillant VM 280/3-5ecoTEC plus / pro (VM heating only)Contrasted
Vaillant VM 282/4-5ecoTEC plus / pro (VM heating only)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 178983 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 178983. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulation pump 178983 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The heating is not working even though the boiler ignites and the burner operates.

    Cause: The circulator is not moving the water through the circuit, so the heat remains in the heat exchanger and does not reach the radiators.

    Touch the pump's outlet pipe with the boiler on: if it is cold while the inlet pipe is hot, the water is not circulating.

  • 02

    There is a buzzing sound in the pump area, but the radiators remain cold.

    Cause: The rotor may have seized due to scale or from the summer shutdown, although the motor is still receiving power.

    With the boiler turned off and cold, try turning the shaft by hand through the slot of the front screw before replacing it.

  • 03

    The boiler shuts down by itself after a few minutes, indicating a circulation or differential pressure fault.

    Cause: If the pump rotates slower than it should for the selected speed, the flow rate falls below the minimum required by the control unit.

    Check the position (speed I or II) of the selector before declaring the pump faulty.

  • 04

    The radiators at the end of the installation remain cold even though the first ones heat up well.

    Cause: A circulator that has lost pumping power is unable to overcome the pressure drop of the entire circuit.

    Bleed the radiators and check the pressure of the expansion vessel before blaming the pump.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.75Pump fault/lack of water: when the pump starts, a sufficient pressure increase is not detected.Blocked/faulty heating pump or with low performance does not generate the expected pressure increase; verify by listening to the start-up, measuring the pressure variation from the sensor, and checking the pump's power supply/communication.
F.23Safety shutdown: flow/return temperature variation too high (lack of circulation).Blocked pump or insufficient flow causes high temperature differential; check pump speed/condition and installation flow, and bleed air.
F.24Safety shutdown: temperature rise too fast (lack of circulation).Blocked pump or reduced power prevents heat evacuation from the heat exchanger, causing the temperature to rise quickly; check that the pump is rotating and its speed (parameters D.014/D.015) and bleed the circuit.
F.22Safety shutdown: lack of water/ water pressure too low in the product.If the pump is blocked or without power, there is no circulation, and the electronics may interpret a lack of water; check the actual circuit pressure, pump rotation/power supply, and wiring to the pump/pressure sensor.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 178983 circulation pump.

Catalogue reference
178983
Brand
Vaillant
Type of part
Pumps
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Model
VPAL-5/2M
Grundfos Reference (P/N)
59866552
Voltage
230V ~50Hz
Condenser
2.5µF
Protection
IP44, TF95
Insulation class
Class H
Maximum pressure
Max. 0.3MPa
Current and power (2 speeds)
0.34A/75W and 0.36A/85W
Production code
PC:ECH
Barcode
07420020042393464298
Vaillant reference
178983
Before purchasing
  • The casing bears the Vaillant brand, but the actual manufacturer of the pump is Grundfos (model VPAL-5/2M, P/N 59866552).
Frequently Asked Questions

Frequently asked questions about the circulator pump 178983

Is it an original pump from Vaillant or from another brand for my VM/VMW?
It has the Vaillant brand on the casing, but the actual manufacturer is Grundfos, model VPAL-5/2M.
What reference do I need to request for this pump from Vaillant VMW 296/3-5?
The 178983 (Vaillant), equivalent to P/N Grundfos 59866552.
Does this pump work for my Vaillant VMW 296/3-5 boiler?
Yes, it is on the list of compatible boilers along with other VM and VMW models, from series 226 to 346.
When should this pump of the Vaillant VM or VMW be replaced?
When the boiler does not heat despite turning on, when the pump makes noise, or when it does not rotate.
How many speeds does the Grundfos VPAL-5/2M pump from Vaillant have?
Two, with 75 W and 85 W of absorbed power.

Spare parts related to Vaillant ecoTEC plus / pro (VMW mixed)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Grundfos Circulating Pump VPAL-5/2M For Vaillant VM/VMW Ref. 178983