Grundfos Circulating Pump UPMO 15-60 VH2004 For Vaillant Boiler Ref. 0020295157
RefurbishedVaillantPumpsGrundfos

Grundfos Circulating Pump UPMO 15-60 VH2004 For Vaillant Boiler Ref. 0020295157

Stock · 1 unit

High-efficiency circulating pump for Vaillant boilers from the VC, VCW, and VU/VUW series, manufactured by Grundfos and branded with Vaillant on the casing. It circulates water in the heating circuit; it is replaced when it seizes, makes noise, or stops circulating. Model UPMO 15-60 VH2004/SPARE, reference 0020295157, confirmed by the label and two independent spare part listings.

VAT included

Compatibility

Vaillant boilers compatible with reference 0010030632

Circulating pump with reference 0010030632. 11 verified compatibilities: VMW 236/3-5 and VM 246/3-5.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 236/3-5ecoTEC PlusContrasted
Vaillant VM 246/3-5ecoTEC PlusContrasted
Vaillant VM 240/3-5ecoTEC PlusContrasted
Vaillant VM 280/3-5ecoTEC PlusContrasted
Vaillant VMW 24/280/3-5ecoTEC PlusContrasted
Vaillant VM 242/4-5ecoTEC PlusContrasted
Vaillant VMW 255/4-7ecoTEC PlusContrasted
Vaillant VMW 346/3-5ecoTEC PlusContrasted
Vaillant VMW 236/3-5ecoTEC ProContrasted
Vaillant ecoTEC Pro 24ecoTEC ProContrasted
Vaillant ecoTEC Pro 28ecoTEC ProContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0010030632 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0010030632. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulation pump 0010030632 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler turns on and seems to work fine, but the heating does not heat or heats very little.

    Cause: The pump is not circulating the water in the circuit even though the boiler is generating heat.

    Check if the radiators furthest from the boiler are cold while the closer ones are heating; this is a typical indication of lack of circulation.

  • 02

    A buzzing or rattling noise is heard in the pump when the heating starts.

    Cause: It usually comes from trapped air in the circuit or a rotor that rubs due to wear.

    Bleed the air from the circuit through the radiators before considering that the pump is faulty.

  • 03

    The pump does not rotate, is seized, or stops shortly after starting.

    Cause: Limescale deposits accumulate on the rotor when the pump remains inactive for extended periods.

    With the cold installation, try to manually free the shaft using the central screw before replacing the pump.

  • 04

    Moisture or dripping appears in the area of the pump motor shaft.

    Cause: The mechanical seal has worn out and no longer properly seals the shaft passage.

    Confirm that the water is coming from the pump body and not from a pipe joint right next to it before purchasing.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.75Pump fault/lack of waterThe UPM3 does not generate the expected pressure increase during the self-check; verify by forcing the pump test (P.0) and checking that it rotates and that the pressure sensor registers Δp.
F.23High differential temperature safety disconnectionA blocked pump or low flow rate causes an excessive difference between flow and return; check the pump's rotation/rpm and ΔT, and review circulation levels in diagnostics.
F.24Safety lockout due to excessively rapid temperature increaseLack of circulation due to blocked/low-performance pump or air; check pump activation, flow-return ΔT, and correct bleeding/filling.
F.320The heating pump is blocked.The circulator rotor is jammed and not delivering flow; check by listening for a humming sound without circulation, perform pump test (T.001) and release or replace.
F.321The pump electronics are faulty.The electronics of the UPM3 do not respond to the command (PWM/230 V) nor report rpm; check power supply/communication and replace if there is no response.
F.322The heating pump is overheating.The circulator's electronics detect overheating (e.g., due to blockage/air); check bleeding and charging, casing temperature, and continuous operation.
F.323The heating pump is running dry.The UPM3 has operated without water (air/insufficient priming) and does not generate flow; check filling and bleed, and replace if it has run dry.
F.324The electrical connection of the pumps has been interrupted.Pump wiring/connector interrupted or harness damaged; check continuity and supply voltage to the pump and repair the harness.
F.325The heating pump has a fault.General fault of the UPM3 (blockage or defective electronics); check with pump test and, if it does not respond or does not deliver flow, replace it.
F.089The integrated heating pump is not suitable for the appliance model.A non-approved UPM3 has been installed for that model and the electronics detect it; confirm by reference/diagnosis and install the correct ref.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the circulator pump Vaillant 0010030632

Catalogue reference
0010030632
Brand
Vaillant
Type of part
Pumps
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Grundfos spare part reference
0020295157
Model/type
UPMO 15-60 VH2004 / SPARE
Additional codes on the label
902247, 452238, 039R41T9
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the circulator pump 0010030632

Is this Grundfos UPMO 15-60 VH2004 pump compatible with the Vaillant VM 246/3-5 boiler?
Yes, the VM 246/3-5 is on the list of Vaillant boilers compatible with this pump.
How many boiler models are compatible with the Grundfos UPMO 15-60 VH2004 pump?
A total of 11 boiler models are compatible with this pump.
What is the reference for the circulation pump used in Vaillant boilers?
The reference for the circulation pump is BCECO236/35.
What symptoms indicate that it is necessary to replace the Grundfos UPMO 15-60 VH2004 pump?
It should be replaced if the pump seizes, makes noise, or stops circulating water in the heating circuit.
What are some of the fault codes associated with this pump?
The documented fault codes are: F.75, F.23, F.24, F.320, F.321, F.322, F.323, F.324, F.325, F.089.